MANCHESTER, NH —
OSHA Inspection: TANK TECH, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of TANK TECH, INC. in 1095 HANOVER ST., MANCHESTER, NH 03109 (NAICS 238990). OSHA activity number 339407215.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TANK TECH, INC.
- Site address
- 1095 HANOVER ST.
- City
- MANCHESTER
- State
- NH
- ZIP
- 03109
- Mailing
- 3897 STATE HIGHWAY H, SIKESTON, MO 63801
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 28, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees working in a permit required confined space were exposed to hazards, including fire or explosion, caused by elevated levels of flammable vapors, and/or delayed rescue from a confined space. (a) Location 1095 Hanover St., Manchester, NH: On or about September 9, 2013, employees entered an underground storage tank classified as a permit required confined space when potential hazards (such as fire and explosion) throughout the space were unknown because the air testing being conducted was not done in a manner that represented the atmosphere throughout the confined space where employees worked. (b) Location 1095 Hanover St., Manchester, NH: On or about September 9, 2013, employees entered an underground storage tank classified as a permit required confined space without using a chest or full body harness to facilitate non-entry rescue. (c) Location 1095 Hanover St., Manchester, NH: On or about September 9, 2013, employees entered an underground storage tank classified as a permit required confined space. When a fire broke out in the confined space, a retrieval tripod was used to extract one of the employees; however, it was defective and failed. A support pin in one of the tripod legs had been replaced by a screwdriver secured by a set of locking pliers.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.134 D03 III B 2
- Issued
- Feb 28, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator ESLI that would ensure cartridges were changed before the end of their service life: (Construction Reference 1926.103) (a) Location - 1095 Hanover St., Manchester, NH: On or about September 9, 2013, employees working in an underground storage tank were using 3M 6800 full face tight fitting elastomeric respirators and the employer had not developed an appropriate change schedule for the respirator cartridges.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1926.405 A02 II E
- Issued
- Feb 28, 2014
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage. (a) Location - 1095 Hanover St., Manchester, NH: On or about September 9, 2013, a temporary light was used to illuminate the inside of an underground storage tank ro employees working inside the tank; the light was not protected from accidental contact or breakage.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1926.407 B02 I
- Issued
- Feb 28, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.407(b)(2)(i): Equipment shall be approved not only for the class of location but also for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that will be present. (a) Location - 1095 Hanover St., Manchester, NH: On or about September 6, 2013, a temporary light was used to illuminate the inside of an underground gasoline storage tank while employees were cleaning it. The light was not assembled in such a way as to make it acceptable for use in a Class I Division 1 location.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 III
- Issued
- Feb 28, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap. (a) Location - 1095 Hanover St., Manchester, NH: On or about September 9, 2013, the flexible cord used to power the resin pump had been spliced and wrapped with electrical tape.
Recent events (2)
- — I (S) $3500
- — Z (S) $3500
1926.416 E01
- Issued
- Feb 28, 2014
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) Location - 1095 Hanover St., Manchester, NH: On or about September 9, 2013, the insulation for flexible cord used to power a light was damaged.
Recent events (2)
- — I (S) $3500
- — Z (S) $3500
More inspections at Tank Tech, INC.
View Tank Tech, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339407215.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.