OSHA Inspection: TANK TECH, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TANK TECH, INC. in 1095 HANOVER ST., MANCHESTER, NH 03109 (NAICS 238990). OSHA activity number 339407215.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tank Tech, INC. — free Get an email when a new federal OSHA severe-injury report for Tank Tech, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TANK TECH, INC.
Site address
1095 HANOVER ST.
City
MANCHESTER
State
NH
ZIP
03109
Mailing
3897 STATE HIGHWAY H, SIKESTON, MO 63801
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
5
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 28, 2014
Abate by
Apr 16, 2014
Penalty
Initial $4,900 · Current $4,900
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that  employees working in a permit required confined space were exposed to hazards, including  fire or explosion, caused by elevated levels of flammable vapors, and/or delayed rescue from a confined space.      (a) Location  1095 Hanover St., Manchester, NH:  On or about September 9, 2013, employees entered an underground storage tank classified as a permit required confined space when potential hazards (such as fire and explosion) throughout the space were unknown because the air testing being conducted was not done in a manner that represented the atmosphere throughout the confined space where employees worked.      (b) Location  1095 Hanover St., Manchester, NH:  On or about September 9, 2013, employees entered an underground storage tank classified as a permit required confined space without using a chest or full body harness to facilitate non-entry rescue.       (c) Location  1095 Hanover St., Manchester, NH:  On or about September 9, 2013, employees entered an underground storage tank classified as a permit required confined space. When a fire broke out in the confined space, a retrieval tripod was used to extract one of the employees; however, it was defective and failed. A  support pin in one of the tripod legs had been replaced by a screwdriver secured by a set of locking pliers.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $4900

1910.134 D03 III B 2

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 28, 2014
Abate by
Apr 16, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator ESLI that would ensure cartridges were changed before the end of their service life: (Construction Reference 1926.103)     (a) Location - 1095 Hanover St., Manchester, NH:   On or about September 9, 2013, employees working in an underground storage tank were using 3M 6800 full face tight fitting elastomeric respirators and the employer had not developed an appropriate change schedule for the respirator cartridges.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1926.405 A02 II E

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2014
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage.   (a) Location - 1095 Hanover St., Manchester, NH:  On or about September 9, 2013, a temporary light was used to illuminate the inside of an underground storage tank ro employees working inside the tank; the light was not protected from accidental contact or breakage.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $4900

1926.407 B02 I

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 28, 2014
Abate by
Apr 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.407(b)(2)(i): Equipment shall be approved not only for the class of location but also for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that will be present.   (a) Location - 1095 Hanover St., Manchester, NH:  On or about September 6, 2013, a temporary light was used to illuminate the inside of an underground gasoline storage tank while employees were cleaning it.  The light was not assembled in such a way as to make it acceptable for use in a Class I Division 1 location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 III

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 28, 2014
Abate by
Apr 16, 2014
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap.   (a) Location - 1095 Hanover St., Manchester, NH:  On or about September 9, 2013, the flexible cord used to power the resin pump had been spliced and wrapped with electrical tape.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $3500

1926.416 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 28, 2014
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a) Location - 1095 Hanover St., Manchester, NH:  On or about September 9, 2013, the insulation for flexible cord used to power a light was damaged.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $3500