BRANDON, MS ·
OSHA Inspection: RAY WASHINGTON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAY WASHINGTON in 108 GILES CIRCLE, BRANDON, MS 39042 (NAICS 238140). OSHA activity number 339407488.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAY WASHINGTON
- Site address
- 108 GILES CIRCLE
- City
- BRANDON
- State
- MS
- ZIP
- 39042
- Mailing
- 113 THOMPSON ROAD, BRANDON, MS 39042
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Oct 21, 2013
- Abate by
- Oct 28, 2013
- Penalty
- Initial $1,800 · Current $450 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (a) Right-side of House - On or about September 6, 2013 employees were exposed to a fall hazard while working on a scaffold that was not fully decked or planked. This scaffold had a 24 inch gap in the scaffold platform. The scaffold platform was 16.6 feet above ground.
Recent events (2)
- · I (S) $450
- · Z (S) $1800
1926.451 C02
- Issued
- Oct 21, 2013
- Abate by
- Oct 28, 2013
- Penalty
- Initial $1,440 · Current $360 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. (a) Right-side of House - On or about September 6, 2013 employees were exposed to a fall hazard while working on a scaffold that had no bases plates installed.
Recent events (2)
- · I (S) $360
- · Z (S) $1440
1926.451 C02 II
- Issued
- Oct 21, 2013
- Abate by
- Oct 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects shall not be used to support scaffolds or platform units. (a) Right-side of House - On or about September 6, 2013 employees were exposed to a fall hazard while working on a scaffold that was placed on unstable objects. One scaffold leg was placed on 4 wooden blocks.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 G01
- Issued
- Oct 21, 2013
- Abate by
- Oct 28, 2013
- Penalty
- Initial $1,800 · Current $450 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. (a) Right-side of House - On or about September 6, 2013 employees were exposed to a fall hazard while working on a welded metal frame scaffold 16.6 feet above ground. Employees were not protected from falling to a lower level by a guardrail system or personal fall arrest system.
Recent events (2)
- · I (S) $450
- · Z (S) $1800
1926.452 C02
- Issued
- Oct 21, 2013
- Abate by
- Oct 28, 2013
- Penalty
- Initial $1,440 · Current $360 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. (a) Right-side of House - On or about September 6, 2013 employees were exposed to a fall hazard while working on a scaffold that was missing 3 sets of cross-braces on the back-side.
Recent events (2)
- · I (S) $360
- · Z (S) $1440
1926.501 B11
- Issued
- Oct 21, 2013
- Abate by
- Oct 28, 2013
- Penalty
- Initial $2,520 · Current $630 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): "Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. (a) Front-side of Roof - On or about September 6, 2013 four employees were exposed to a fall hazard while working on a steep roof 25 feet above ground. The roof had a pitch of 6/12. Employees were not protected from falling to a lower level by a guardrail system or personal fall arrest system or safety net system.
Recent events (2)
- · I (S) $630
- · Z (S) $2520
More inspections in this industry (NAICS 238140)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339407488.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.