On , OSHA opened a referral safety inspection of SELECTIVE TRANSPORTATION CORPORATION in 19 CROWS MILL RD, KEASBEY, NJ 08832 (NAICS 493110). OSHA activity number 339407587.

Watch Selective Transportation Corporation — free Get an email when a new federal OSHA severe-injury report for Selective Transportation Corporation is published. One employer, no account, unsubscribe in one click.
Site address
19 CROWS MILL RD
City
KEASBEY
State
NJ
ZIP
08832
Mailing
19 CROWS MILL RD, KEASBEY, NJ 08832
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
100
Ownership type
A

11 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $2550.00 · Current $1658.00 Reduced
29 CFR 1910.36(d)(1): Exit(s) were locked or fastened,, preventing free escape from inside of the building:      a/ Selective Transportation/Keasbey NJ Site: Warehouse.  In the event of a fire or other emergency:    1/Exit door leading to the exterior shipping/receiving/parking area of the facility was locked by a sliding lock, preventing free escape from the building.  2/Two metal gates dividing warehouse storage areas were locked and required a key to be opened, preventing free escape from various sections of the warehouse to the nearest exit.    Observed on/or about 09/09/2013.
Recent events (2)
  • — I (S) $1658
  • — Z (S) $2550

1910.37 A03

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $2550.00 · Current $1658.00 Reduced
29 CFR 1910.37(a)(3):   Exit routes were not continuously maintained free of obstructions or impediments to full instant use in the case of fire or other emergency:    a/ Selective Transportation/Keasbey NJ Site: Warehouse/Miele Eye Wash Station Area.  Emergency exit door leading to the exterior shipping/receiving/parking area of the facility was blocked by a plastic waste container, water hose, and 2 plastic floor cleaning buckets.    Observed on/or about 09/09/2013.
Recent events (2)
  • — I (S) $1658
  • — Z (S) $2550

1910.37 B04

Serious Gravity 1 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1658.00 Reduced
29 CFR 1910.37(b)(4): Sign(s) reading "EXIT", or similar designation, with an arrow indicating the direction, were not placed in every location where the direction of travel to reach the nearest exit was not immediately apparent:    a/ Selective Transportation/Keasbey NJ Site: Warehouse. Throughout the warehouse directional exit signs were not provided to show nearest exit route in the event of a fire or other emergency.    Observed on/or about 9/9/2013.
Recent events (2)
  • — I (S) $1658
  • — Z (S) $2550

1910.110 D10

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2763.00 Reduced
29 CFR 1910.110(d)(10): Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic:     a/ Selective Transportation/Keasbey NJ Site: Yard Shipping/Receiving Area. Propane tanks stored near the waste Container dumpster (full/empty) used to power forklift equipment were not positioned a minimum 10 ft. away from vehicle traffic. Equipment: Double metal cage 16 to 20 tank capacity and 11 Propane Tanks.     Observed on/or about 09/09/2013.
Recent events (2)
  • — I (S) $2763
  • — Z (S) $4250

1910.110 F02 II

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.110(f)(2)(ii):  LP gas container(s) stored inside were located near or in area(s) normally used or intended for the safe exit of employees:    a/ Selective Transportation/Keasbey NJ Site: Warehouse. Propane tanks (full and/or empty) used to power forklift trucks were randomly stored throughout the warehouse near metal beams, at dock Bay doors, near an exit door and near storage racks where empls. are required to walk, work, and access the nearest aisle or exit.   Observed on/or about 9/9/2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.110 F06 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.110(f)(6)(ii):  LP gas container(s) stored outside of buildings were not in a suitable enclosure or otherwise protected against tampering:    a/ Selective Transportation/Keasbey NJ Site: Yard Shipping/Receiving Area. Propane tanks (full and/or empty) used to power forklift trucks were not properly stored in that 10 Propane tanks were stored outside of the approved metal cage provided for storage.  Observed on/or about 9/9/2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A05

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2763.00 Reduced
29 CFR 1910.178(a)(5):  Nameplates or markings for powered industrial trucks that were equipped with front-end attachments other than factory installed attachments, the user did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:    a/ Selective Transportation/Keasbey NJ Site: Warehouse.  Komatsu 25 forklift truck (including but not limited to) with a clamp attachment that was not factory installed has not been rated and provided with a tag/label to show the combined weight capacity of the truck and attachment.    Observed on/or about 09/09/2013.
Recent events (2)
  • — I (S) $2763
  • — Z (S) $4250

1910.178 L04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $3247.00 Reduced
29 CFR 1910.178(l)(4)(iii): The employer did not ensure that an evaluation of each powered Industrial truck operator's performance was conducted at least once every three years.     a/ Selective Transportation/Keasbey NJ Site:  Warehouse. Fork-lift operators who were previously trained were not evaluated relative to the fork-lift training previously provided at least every 3 years. The last training/evaluation conducted was in 2011 and was not updated to include all designated permanent and temp operators hired thereafter. Equipment includes but not limited to - 17 Propane powered, 3 Electrical powered sit down type clamp/forklift trucks and one Electrical powered Hi-Lo rider.    Observed on/or about 9/9/2013
Recent events (2)
  • — I (S) $3247
  • — Z (S) $5000

1910.178 M03

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2763.00 Reduced
29 CFR 1910.178(m)(3):  A safe place to ride was not provided where riding a powered industrial truck(s) was authorized:      a/ Selective Transportation/Keasbey NJ Site: Warehouse. Prime Mover Hi Lo electrical powered rider with extended reach was not provided with fall protection in that    1/ There was no guard rail on the Hi Lo where an employee would stand to operate the controls.  2/ The chain or similar device used to prevent employee from falling was missing.  3/ A lanyard and belt or harness were not provided    Observed on/or about 09/09/2013.
Recent events (2)
  • — I (S) $2763
  • — Z (S) $4250

1910.212 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2763.00 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by crushing action of horizontal ram.     a/ Selective Transportation/Keasbey NJ Site: Warehouse C&F Waste Compactor area.     C&F Waste Compactor gate provided to prevent employees from being exposed to moving compactor ram was inadequate, in that the gate had no limit switch and/or other approved means to prevent the compactor ram from moving when the gate was open.    Observed on/or about 09/09/2013.
Recent events (2)
  • — I (S) $2763
  • — Z (S) $4250

1910.157 E03

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a/ Selective Transportation/Keasbey NJ Site: Warehouse. Portable fire extinguishers located on walls and beams were not all tagged to indicate they have been inspected on an annual basis. Tags on several extinguishers were dated 2009 and 2010.  Observed on/or about 9/9/2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0