MARCUS HOOK, PA —
OSHA Inspection: ALAN MCILVAIN COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALAN MCILVAIN COMPANY in 501 MARKET ST, MARCUS HOOK, PA 19061 (NAICS 423310). OSHA activity number 339408064.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALAN MCILVAIN COMPANY
- Site address
- 501 MARKET ST
- City
- MARCUS HOOK
- State
- PA
- ZIP
- 19061
- Mailing
- PO BOX 380, MARCUS HOOK, PA 19061
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 85
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.176 A
- Issued
- Dec 6, 2013
- Abate by
- Jan 23, 2014
- Penalty
- Initial $3,500 · Current $1,900 Reduced
General-duty citation text
29 CFR 1910.176(a): Permanent aisles or passageways were not appropriately marked: a) 501 Market St, Marcus Hook, PA - Throughout all warehouses - Aisles and passageways were not appropriately marked where the company was using powered industrial trucks (PIT), thus exposing the employees to struck-by hazards. This violation was observed on or about August 28, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1900
- — Z (S) $3500
1910.215 B09
- Issued
- Dec 6, 2013
- Penalty
- Initial $4,200 · Current $2,900 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: a) 501 Market St, Marcus Hook, PA - Mill - The 3400 RPM Wissota ball Bearing bench grinder, Model #8.8, was not equipped with a peripheral protecting member, exposing the employees to a struck-by hazard. This violation was observed on or about August 28, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2900
- — Z (S) $4200
1910.303 B07 I
- Issued
- Dec 6, 2013
- Abate by
- Dec 12, 2013
- Penalty
- Initial $4,900 · Current $3,200 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes in electrical cabinets were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) 501 Market St, Marcus Hook, PA Distribution warehouse Live parts were not effectively closed, missing circuit breakers/blanks, in the energized (110 Volts) electrical circuit breaker panel were not guarded against accidental contact, exposing the employees to a shock/electrocution hazard. This violation was observed on or about August 28, 2013. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $3200
- — Z (S) $4900
1910.156 D
- Issued
- Dec 6, 2013
- Abate by
- Dec 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.156(d): Inspection of fire fighting equipment was not performed at least annually to assure the safe operational condition of the equipment: a) 501 Market St, Marcus Hook, PA Mill The company did not inspect 3 fire extinguishers at least annually to ensure the safe operation of the equipment., thus exposing the employees to a fire hazard. This violation was observed on or about August 28, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Alan Mcilvain Company