CARLSTADT, NJ —
OSHA Inspection: HARTIN PAINT & FILLER CORP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HARTIN PAINT & FILLER CORP in 219 BROAD ST, CARLSTADT, NJ 07072 (NAICS 325510). OSHA activity number 339409575.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARTIN PAINT & FILLER CORP
- Site address
- 219 BROAD ST
- City
- CARLSTADT
- State
- NJ
- ZIP
- 07072
- Mailing
- 219 BROAD ST, CARLSTADT, NJ 07072
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 C01
- Issued
- Mar 7, 2014
- Penalty
- Initial $2,520 · Current $2,016 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) Exterior Above Ground Storage Tank Area: Employees were exposed to a fall hazard of approximately 10 feet while measuring the contents of an Exterior Above Ground Storage Tank containing Toluol, Ethyl Acetate and Normal Butyl Acetate that was not equipped with a guard rail system, on or about 9/11/2013.
Recent events (3)
- — F (S) $2016
- — C (S) $2520
- — Z (S) $2520
1910.24 B
- Issued
- Mar 7, 2014
- Penalty
- Initial $1,800 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: a) Exterior Above Ground Storage Tank Area: Fixed stairs were not provided for employees measuring the contents of an exterior above ground storage tank containing Toluol, Ethyl Acetate and Normal Butyl Acetate, on or about 9/11/2013.
Recent events (3)
- — F (S) $1440
- — C (S) $1800
- — Z (S) $1800
1910.26 C02 IV
- Issued
- Mar 7, 2014
- Penalty
- Initial $1,800 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.26(c)(2)(iv): Ladders must be maintained in good usable condition at all times. a) Exterior Above Ground Storage Tank Area: The top of the metal ladder used to access the exterior tank containing Toluol, Ethyl Acetate and Normal Butyl Acetate was not maintained in a good usable condition, on or about 9/11/2013.
Recent events (3)
- — F (S) $1440
- — C (S) $1800
- — Z (S) $1800
1910.110 B06 VI
- Issued
- Mar 7, 2014
- Penalty
- Initial $1,800 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.110(b)(6)(vi): Readily ignitable material such as weeds and long dry grass shall be removed within 10 feet of any container. a) Exterior Above Ground Storage Tank Area: Four LP-Gas cylinders were stored in a long dry grass area approximately 15 feet from an exterior above ground storage tank containing Toluol, Ethyl Acetate and Normal Butyl Acetate, on or about 9/16/2013.
Recent events (3)
- — F (S) $1440
- — C (S) $1800
- — Z (S) $1800
1910.110 B06 VII
- Issued
- Mar 7, 2014
- Penalty
- Initial $1,800 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.110(b)(6)(vii): The minimum separation between liquefied petroleum gas containers and flammable liquid tanks shall be 20 feet, and the minimum separation between a container and the centerline of the dike shall be 10 feet. The foregoing provision shall not apply when LP-Gas containers of 125 gallons or less capacity are installed adjacent to Class III flammable liquid tanks of 275 gallons or less capacity. a) Exterior Above Ground Storage Tank Area: LP-Gas cylinders were stored next to a dike wall for an exterior above ground storage tank containing Toluol, Ethyl Acetate and Normal Butyl Acetate, on or about 9/16/2013.
Recent events (3)
- — F (S) $1440
- — C (S) $1800
- — Z (S) $1800
1910.110 F02 I
- Issued
- Mar 7, 2014
- Penalty
- Initial $1,800 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): LP-Gas Containers were not stored in a manner to minimize exposure to excessive temperature rise, physical damange, or tampering by unauthorized persons a) Exterior Above Ground Storage Tank Area: Compressed gas cylinders containing propane were unsecured next to an exterior above ground storage tank containing Toluol, Ethyl Acetate and Normal Butyl Acetate, on or about 9/16/2013. b) Outside Compressor Room Area: Compressed gas cylinders containing propane were stored outside the compressor room, on or about 9/16/2013.
Recent events (3)
- — F (S) $1440
- — C (S) $1800
- — Z (S) $1800
1910.178 L01 I
- Issued
- Mar 7, 2014
- Penalty
- Initial $1,800 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Throughout Facility: The employer did not ensure that the operator of a powered industrial truck had successfully completed the training on the safe operation of a powered industrial truck, on or about 9/11/2013.
Recent events (3)
- — F (S) $1440
- — C (S) $1800
- — Z (S) $1800
More inspections at Hartin Paint & Filler Corp
View Hartin Paint & Filler Corp's full OSHA safety record →
More inspections in this industry (NAICS 325510)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339409575.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.