Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CO FALTER CONSTRUCTION CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CO FALTER CONSTRUCTION CORPORATION in LOWER HARBOR BROOK CSO STORAGE FACILITY 333 STATE FAIR BLVD, SYRACUSE, NY 13204 (NAICS 237110). OSHA activity number 339410821.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CO Falter Construction Corporation for free Get an email when a new federal OSHA severe-injury report for CO Falter Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
LOWER HARBOR BROOK CSO STORAGE FACILITY 333 STATE FAIR BLVD
City
SYRACUSE
State
NY
ZIP
13204
Mailing
403 BEAR STREET W., SYRACUSE, NY 13204
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
130
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B01

Other-than-serious 1 instance 6 exposed
Issued
Sep 26, 2013
Penalty
Initial $6,300 · Current $3,250 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a) Lower Harbor Brook CSO Storage Facility Mechanical Building - On or about 21 August, 2013 - Employees were working on the roof working level above 6 feet above the lower level without the use of personal fall protection.
Recent events (3)
  • · J (O) $3250
  • · C (S) $6300
  • · Z (S) $6300

1926.701 B

Deleted Serious Gravity 5 4 instances 6 exposed
Issued
Sep 26, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:  a) Lower Harbor Brook CSO Storage Facility Mechanical Building - On or about 21 August, 2013 - Employees were exposed to unprotected protruding reinforcing steel while working on the roof working surface installing grout.