GREEN BAY, WI ·
OSHA Inspection: BAY CONVERTING INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BAY CONVERTING INC in 1330 ELIZABETH STREET, GREEN BAY, WI 54302 (NAICS 322221). OSHA activity number 339410904.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAY CONVERTING INC
- Site address
- 1330 ELIZABETH STREET
- City
- GREEN BAY
- State
- WI
- ZIP
- 54302
- Mailing
- 1330 ELIZABETH STREET, GREEN BAY, WI 54302
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322221
- Employees
- 17
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Oct 17, 2013
- Abate by
- Nov 23, 2013
- Penalty
- Initial $1,360 · Current $950 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by the unused portion of a rotating band saw blade: a) On or about September 11, 2013, the adjustable guard installed on the two (2) JET cut saws used in the maintenance department did not cover the unused portion of the reciprocating blade while the saws were in use. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- · I (S) $950
- · Z (S) $1360
1910.304 F01 VIII
- Issued
- Oct 17, 2013
- Abate by
- Nov 7, 2013
- Penalty
- Initial $1,360 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(viii): The employer shall ensure that all circuit breakers used as switches are labelled "SWD": a) On or about September 11, 2013, circuit breakers used as light switches in the Second Storage Warehouse were not marked "SWD". b) On or about September 11, 2013, circuit breakers used as light switches in the Coating Department Storage area were not marked "SWD". Abatement Certification and Abatement Documentation Required.