VESTAL, NY ·
OSHA Inspection: STC STAR CORPORATION DBA HILLCREST CARSTAR
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of STC STAR CORPORATION DBA HILLCREST CARSTAR in 2813 OLD VESTAL ROAD, VESTAL, NY 13850 (NAICS 811121). OSHA activity number 339411498.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STC STAR CORPORATION DBA HILLCREST CARSTAR
- Site address
- 2813 OLD VESTAL ROAD
- City
- VESTAL
- State
- NY
- ZIP
- 13850
- Mailing
- 2813 OLD VESTAL ROAD, VESTAL, NY 13850
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 28
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.134 E01
- Issued
- Sep 27, 2013
- Abate by
- Nov 28, 2013
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note: The employer may discontinue an employees medical evaluations when the employee is no longer required to use a respirator. a) Throughout the facility, on or about 9/11/13: Employee required to wear a half face air purifying respirator and had not been provided with a medical evaluation.
Recent events (2)
- · I (S) $1249.5
- · Z (S) $1785
1910.134 F02
- Issued
- Sep 27, 2013
- Abate by
- Oct 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: a) Throughout the facility, on or about 9/11/13: Employees required to wear half face air purifying respirators had not been fit tested. Last fit test was 5 years ago.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.215 A04
- Issued
- Sep 27, 2013
- Abate by
- Nov 28, 2013
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Truck Department, on or about 9/11/13: A Delta Shop Master Bench Grinder had an opening between the work rest and grinding wheel that measured 1 1/2 inch at the left wheel.
Recent events (2)
- · I (S) $1249.5
- · Z (S) $1785
1910.215 B09
- Issued
- Sep 27, 2013
- Abate by
- Oct 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Truck Department, on or about 9/11/13: A Delta Shop Master Bench Grinder had an opening between the tongue guard and grinding wheel that measured 1 1/4-inch at the left wheel.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1904.32 B03
- Issued
- Sep 27, 2013
- Abate by
- Oct 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(b)(3): The 300A annual summary was not certified by a company executive to ensure that he or she has examined the OSHA 300 Log and that he or she reasonably believes, based on his or her knowledge of the process by which the information was recorded, that the annual summary is correct and complete. a) STC Star Corporation dba Hillcrest Carstar, on or about 9/11/13: The 2012 OSHA 300A was not properly certified. There were recordable cases not recorded on the 2012 OSHA 300 Log.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 811121)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339411498.