Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: OSC EQUIPMENT SERVICES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OSC EQUIPMENT SERVICES, INC. in 333 GANSON STREET, BUFFALO, NY 14203 (NAICS 811310). OSHA activity number 339412959.

Watch OSC Equipment Services, INC. — free Get an email when a new federal OSHA severe-injury report for OSC Equipment Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
333 GANSON STREET
City
BUFFALO
State
NY
ZIP
14203
Mailing
333 GANSON STREET, BUFFALO, NY 14203
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II C

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.    a) On or about 09/12/2013 in the shop, where the energy control program did not outline and document specific steps for removal of lockout devices by other than the employee who applied the device.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $2975

1910.147 C06 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about 09/12/2013 in the shop, where employees perform servicing and maintenance such as, but not limited to: changing band saw blades, press brake dies and the shear blade on the Cincinnati shear.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) On ior about 09/12/2013 in the engine rebuild area; where an extension cord was run in place of fixed wiring to supply power to a parts washer.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339412959.