Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TALLEY IRON WORKS, LLC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of TALLEY IRON WORKS, LLC in 67740 HIGHWAY 41, PEARL RIVER, LA 70452 (NAICS 332312). OSHA activity number 339414518.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Talley Iron Works, LLC — free Get an email when a new federal OSHA severe-injury report for Talley Iron Works, LLC is published. One employer, no account, unsubscribe in one click.
Site address
67740 HIGHWAY 41
City
PEARL RIVER
State
LA
ZIP
70452
Mailing
P.O. BOX 1710, TALISHEEK, LA 70464
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
6
Ownership type
A

8 citations on file for this inspection.

1910.106 D03 II

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Dec 23, 2013
Abate by
Jan 13, 2014
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.106(d)(3)(ii): Storage cabinet(s) for flammable and combustible liquids were not designed or constructed to meet minimal fire resistance as required.  On or about September 13th 2013, the employer failed to ensure that flammable paint was stored in a proper area. Approximately 25 gallons of flammable paint were stored in the employee bathroom.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1910.179 J02

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Dec 23, 2013
Abate by
Jan 6, 2014
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.179(j)(2): The overhead crane was not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard.  On or about September 13 2013, the employer failed to ensure that frequent inspections were being conducted on the Dayton overhead hoist in the shop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1910.243 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 23, 2013
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel.    On or about September 13th 2013, the employer failed to ensure that the angle grinders being used were equipped with safety guards. The grinders were being used in the welding area of the shop to grind metal so that is has a clean surface on which to weld.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.253 E01

Other-than-serious 1 instance 2 exposed
Issued
Dec 23, 2013
Penalty
Initial $1,020 · Current $0 Reduced
29 CFR 1910.253(e)(1): Equipment was not installed and used only in the service for which it was approved and as recommended by the manufacturer.    On or about September 13th, 2013, in the welding and cutting area of the shop, the employer failed to ensure that the pressure regulator on a propane cylinder was properly maintained. The glass covering that protects the gauges in the regulator was missing. The propane cylinder was used as the fuel gas for an oxygen-fuel gas cutting torch.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1020

1910.303 B01

Serious Gravity 1 4 instances 2 exposed
Issued
Dec 23, 2013
Abate by
Jan 13, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees.    On or about September 13th 2013, the employer failed to ensure that the wiring that existed in the shop building was free from recognized hazards. The lighting in the building was wired with extension cords that were spliced, taped and had exposed inner conductors.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 23, 2013
Abate by
Jan 6, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.    On or about September 13 2013, the employer failed to ensure power (on/off) switches were installed for the lighting used in the welding shop. Circuit breaker 37 in the shop's panel box was being used as the power switch for the lighting.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.334 A02 II

Serious Gravity 1 2 instances 2 exposed
Issued
Dec 23, 2013
Abate by
Jan 6, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:    On or about September 13th 2013, in the welding shop area, the employer failed to ensure that damaged electrical extension cords were removed from service. An extension cord had a four inch section of the outer sheath missing which exposed the inner conductors.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.178 L04 III

Other-than-serious 1 instance 2 exposed
Issued
Dec 23, 2013
Abate by
Jan 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.  On or about September 13th 2013, the employer failed to ensure that the forklift operator, Flint Broom, had his forklift certification reevaluated. The certifcation the employee had on site had been issued in 2004 and the employee had not had any training or evaluation since being issued the certification in 2004.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Talley Iron Works, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339414518.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.