PEARL RIVER, LA —
OSHA Inspection: TALLEY IRON WORKS, LLC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of TALLEY IRON WORKS, LLC in 67740 HIGHWAY 41, PEARL RIVER, LA 70452 (NAICS 332312). OSHA activity number 339414518.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TALLEY IRON WORKS, LLC
- Site address
- 67740 HIGHWAY 41
- City
- PEARL RIVER
- State
- LA
- ZIP
- 70452
- Mailing
- P.O. BOX 1710, TALISHEEK, LA 70464
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.106 D03 II
- Issued
- Dec 23, 2013
- Abate by
- Jan 13, 2014
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii): Storage cabinet(s) for flammable and combustible liquids were not designed or constructed to meet minimal fire resistance as required. On or about September 13th 2013, the employer failed to ensure that flammable paint was stored in a proper area. Approximately 25 gallons of flammable paint were stored in the employee bathroom.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.179 J02
- Issued
- Dec 23, 2013
- Abate by
- Jan 6, 2014
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.179(j)(2): The overhead crane was not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard. On or about September 13 2013, the employer failed to ensure that frequent inspections were being conducted on the Dayton overhead hoist in the shop.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.243 C03
- Issued
- Dec 23, 2013
- Penalty
- Initial $1,360 · Current $816 Reduced
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel. On or about September 13th 2013, the employer failed to ensure that the angle grinders being used were equipped with safety guards. The grinders were being used in the welding area of the shop to grind metal so that is has a clean surface on which to weld.
Recent events (2)
- — I (S) $816
- — Z (S) $1360
1910.253 E01
- Issued
- Dec 23, 2013
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(e)(1): Equipment was not installed and used only in the service for which it was approved and as recommended by the manufacturer. On or about September 13th, 2013, in the welding and cutting area of the shop, the employer failed to ensure that the pressure regulator on a propane cylinder was properly maintained. The glass covering that protects the gauges in the regulator was missing. The propane cylinder was used as the fuel gas for an oxygen-fuel gas cutting torch.
Recent events (2)
- — I (O) $0
- — Z (S) $1020
1910.303 B01
- Issued
- Dec 23, 2013
- Abate by
- Jan 13, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees. On or about September 13th 2013, the employer failed to ensure that the wiring that existed in the shop building was free from recognized hazards. The lighting in the building was wired with extension cords that were spliced, taped and had exposed inner conductors.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.303 B02
- Issued
- Dec 23, 2013
- Abate by
- Jan 6, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. On or about September 13 2013, the employer failed to ensure power (on/off) switches were installed for the lighting used in the welding shop. Circuit breaker 37 in the shop's panel box was being used as the power switch for the lighting.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.334 A02 II
- Issued
- Dec 23, 2013
- Abate by
- Jan 6, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: On or about September 13th 2013, in the welding shop area, the employer failed to ensure that damaged electrical extension cords were removed from service. An extension cord had a four inch section of the outer sheath missing which exposed the inner conductors.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.178 L04 III
- Issued
- Dec 23, 2013
- Abate by
- Jan 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years. On or about September 13th 2013, the employer failed to ensure that the forklift operator, Flint Broom, had his forklift certification reevaluated. The certifcation the employee had on site had been issued in 2004 and the employee had not had any training or evaluation since being issued the certification in 2004.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Talley Iron Works, LLC
View Talley Iron Works, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339414518.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.