DRIPPING SPRINGS, TX ·
OSHA Inspection: A-LINE AUTO PARTS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of A-LINE AUTO PARTS in 2200 WEST HIGHWAY 290, DRIPPING SPRINGS, TX 78620 (NAICS 441310). OSHA activity number 339416232.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A-LINE AUTO PARTS
- Site address
- 2200 WEST HIGHWAY 290
- City
- DRIPPING SPRINGS
- State
- TX
- ZIP
- 78620
- Mailing
- 2200 WEST HIGHWAY 290, DRIPPING SPRINGS, TX 78620
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 6
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.141 A05
- Issued
- Nov 5, 2013
- Abate by
- Nov 13, 2013
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.141(a)(5): Enclosed workplaces were not so constructed, equipped, and maintained as to prevent the entrance or harborage of rodents, insects, or other vermin: On or about, September 13, 2013, the employer did not ensure that the establishment was free for vermin in and around the work and eating areas, exposing employees to unsanitary working conditions.
Recent events (2)
- · I (S) $1620
- · Z (S) $2700
1910.305 C04
- Issued
- Nov 5, 2013
- Abate by
- Nov 13, 2013
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface: On or about September 13, 2013, the faceplate in the employee/public restroom was damaged, exposing the employees to the hazard of electrical shock.
Recent events (2)
- · I (S) $1620
- · Z (S) $2700
1910.305 G01 IV A
- Issued
- Nov 5, 2013
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about September 13, 2013, three flexible electrical cords were connected together to provide power to a 12 volt radio in the rear of the establishment, exposing the employees to electrical hazards.