Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SILVERADO STEEL SOLUTIONS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SILVERADO STEEL SOLUTIONS, LLC in 1450 N. 1ST STREET, GARLAND, TX 75040 (NAICS 327910). OSHA activity number 339417768.

Watch Silverado Steel Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Silverado Steel Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1450 N. 1ST STREET
City
GARLAND
State
TX
ZIP
75040
Mailing
1450 N. 1ST STREET, GARLAND, TX 75040
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327910
Employees
21
Ownership type
A

5 citations on file for this inspection.

1910.254 D09 III

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $280.00 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced. Joining lengths of work and electrode cables were not done by the use of connecting means specifically intended for the purpose. The connecting means did not have insulation adequate for the service conditions:     On or about September 09, 2013, employees working at the facility were using a Miller Arc welding machine with the flexible cord spliced.
Recent events (2)
  • — I (S) $280
  • — Z (S) $2800

1910.303 B02

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $280.00 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled equipment were not installed and used in accordance with any instructions included in the listing or labeling:    On or about September 09, 2013, employees worked in the facility where the metallic receptacle was on the floor and not mounted to the wall.
Recent events (2)
  • — I (S) $280
  • — Z (S) $2800

1910.305 B01 II

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:  On or about September 09, 2013, employees worked in the facility where an electrical panel box was missing blanks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 2 instances 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): The employer did not provide portable fire extinguishers and did not mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury:  On or about September 16, 2013, employees worked at the facility where fire extinguishers were blocked and were not available for use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 6 instances 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): The employer did not assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer did not record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record was not be available to the Assistant Secretary upon request:  On or about September 09, 2013, employees were working at the facility where fire extinguishers were not maintained and had an inspection date of 2008.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339417768.