OSHA Inspection: OKON METALS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OKON METALS INC. in 2001 S. RIVERFRONT BLVD., DALLAS, TX 75207 (NAICS 423930). OSHA activity number 339417917.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Okon Metals INC. — free Get an email when a new federal OSHA severe-injury report for Okon Metals INC. is published. One employer, no account, unsubscribe in one click.
Establishment
OKON METALS INC.
Site address
2001 S. RIVERFRONT BLVD.
City
DALLAS
State
TX
ZIP
75207
Mailing
2001 S. RIVERFRONT BLVD., DALLAS, TX 75207
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
22
Ownership type
A

10 citations on file for this inspection.

1910.22 A01

Other-than-serious 1 instance 7 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $2,800 · Current $600 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition:    The employer did not ensure that all places of employment, and passageways were kept clean and orderly and in a sanitary condition.  This violation was observed on September 17, 2013, in the yard, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where debris and leaking oil on the ground creating slipping, tripping, and falling hazards.
Recent events (2)
  • — I (O) $600
  • — Z (S) $2800

1910.37 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $3,500 · Current $1,400 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    This violation was observed on September 17, 2013, in the metal separation shop, building #3, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where exit door was locked.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $3500

1910.178 P01

Deleted Serious Gravity 5 3 instances 2 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition:  The employer did not ensure industrial truck found to be in need of repair, defective, or in any way unsafe be taken out of service until restored to safe operating condition.  This violation occurred on September 17, 2013, and at times prior thereto, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where employees operated Prentice 410E, specification #38 that found to be in need of repair, defective, or in any way unsafe had not been taken out of service:  a)  The windshield was broken.  b)  It was leaking oil.  c)  The right window was missing/broken.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.212 A05

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $2,800 · Current $1,100 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    The employer did not ensure fan blade guard did not have openings larger than one half inch.  This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where at least one (1) fan in use had openings in the guard larger than one half inch.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2800

1910.304 G05

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    This violation was observed on September 4, 2013, in the repair shop, building #1, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where employees were exposed to electrical hazards while using fan that was missing ground pin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $3,500 · Current $700 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    The employer did not ensure electrical equipment  is used and installed in accordance with the listing or labeling instructions.  This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace at 2001 S. Riverfront Blvd., Dallas, TX; where a metal electrical box designed to be installed inside of a wall was used on the end of an extension cord powering welders.
Recent events (2)
  • — I (O) $700
  • — Z (S) $3500

1910.303 F02

Other-than-serious 1 instance 3 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    The employer did not legibly mark to indicate the purpose of each service, feeder and branch circuit, at its disconnecting means or overcurrent device.  This violation was observed on or about September 17, 2013, in the repair shop, building #1, located at 2001 S. Riverfront Blvd., Dallas, TX; where circuit breaker panel was not marked to indicate the purpose of individual breakers.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1910.305 B01 II

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $2,800 · Current $1,100 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    The employer did not close unused openings on electrical equipment.  This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where electrical panel was missing circuit breaker.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2800

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $2,800 · Current $1,100 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    The employer did not ensure flexible cords were connected to devices and fittings so that tension was not transmitted to joints or terminal screws. This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where the flexible cord of a metal electrical box used to power welders did not have strain relief device causing a transmission of tension to joints and or terminals.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2800

1910.305 J01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact:    The employer did not install a cover, faceplate, or fixture canopy in each outlet receptacle box in completed installations.  This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace located 2001 S. Riverfront Blvd., Dallas, TX; where employees were not protected from contacting energized parts while utilizing the outlet receptacle box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

View Okon Metals INC.'s full OSHA safety record →