DALLAS, TX —
OSHA Inspection: OKON METALS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of OKON METALS INC. in 2001 S. RIVERFRONT BLVD., DALLAS, TX 75207 (NAICS 423930). OSHA activity number 339417917.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OKON METALS INC.
- Site address
- 2001 S. RIVERFRONT BLVD.
- City
- DALLAS
- State
- TX
- ZIP
- 75207
- Mailing
- 2001 S. RIVERFRONT BLVD., DALLAS, TX 75207
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 22
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 A01
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $2,800 · Current $600 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition: The employer did not ensure that all places of employment, and passageways were kept clean and orderly and in a sanitary condition. This violation was observed on September 17, 2013, in the yard, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where debris and leaking oil on the ground creating slipping, tripping, and falling hazards.
Recent events (2)
- — I (O) $600
- — Z (S) $2800
1910.37 A03
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $3,500 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: This violation was observed on September 17, 2013, in the metal separation shop, building #3, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where exit door was locked.
Recent events (2)
- — I (S) $1400
- — Z (S) $3500
1910.178 P01
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition: The employer did not ensure industrial truck found to be in need of repair, defective, or in any way unsafe be taken out of service until restored to safe operating condition. This violation occurred on September 17, 2013, and at times prior thereto, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where employees operated Prentice 410E, specification #38 that found to be in need of repair, defective, or in any way unsafe had not been taken out of service: a) The windshield was broken. b) It was leaking oil. c) The right window was missing/broken.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.212 A05
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $2,800 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: The employer did not ensure fan blade guard did not have openings larger than one half inch. This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where at least one (1) fan in use had openings in the guard larger than one half inch.
Recent events (2)
- — I (S) $1100
- — Z (S) $2800
1910.304 G05
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: This violation was observed on September 4, 2013, in the repair shop, building #1, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where employees were exposed to electrical hazards while using fan that was missing ground pin.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.303 B02
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $3,500 · Current $700 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: The employer did not ensure electrical equipment is used and installed in accordance with the listing or labeling instructions. This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace at 2001 S. Riverfront Blvd., Dallas, TX; where a metal electrical box designed to be installed inside of a wall was used on the end of an extension cord powering welders.
Recent events (2)
- — I (O) $700
- — Z (S) $3500
1910.303 F02
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: The employer did not legibly mark to indicate the purpose of each service, feeder and branch circuit, at its disconnecting means or overcurrent device. This violation was observed on or about September 17, 2013, in the repair shop, building #1, located at 2001 S. Riverfront Blvd., Dallas, TX; where circuit breaker panel was not marked to indicate the purpose of individual breakers.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1910.305 B01 II
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $2,800 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: The employer did not close unused openings on electrical equipment. This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where electrical panel was missing circuit breaker.
Recent events (2)
- — I (S) $1100
- — Z (S) $2800
1910.305 G02 III
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $2,800 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: The employer did not ensure flexible cords were connected to devices and fittings so that tension was not transmitted to joints or terminal screws. This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace located at 2001 S. Riverfront Blvd., Dallas, TX; where the flexible cord of a metal electrical box used to power welders did not have strain relief device causing a transmission of tension to joints and or terminals.
Recent events (2)
- — I (S) $1100
- — Z (S) $2800
1910.305 J01 I
- Issued
- Mar 11, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact: The employer did not install a cover, faceplate, or fixture canopy in each outlet receptacle box in completed installations. This violation was observed on or about September 17, 2013, in the repair shop, building #1, at a workplace located 2001 S. Riverfront Blvd., Dallas, TX; where employees were not protected from contacting energized parts while utilizing the outlet receptacle box.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
More inspections at Okon Metals INC.
View Okon Metals INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339417917.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.