Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: L & L DRYWALL & CONSTRUCTION CO., INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of L & L DRYWALL & CONSTRUCTION CO., INC. in BLDG. 308 ACEDEMY STREET, POPE AFB, NC 28308 (NAICS 238310). OSHA activity number 339420424.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch L & L Drywall & Construction CO., INC. — free Get an email when a new federal OSHA severe-injury report for L & L Drywall & Construction CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
BLDG. 308 ACEDEMY STREET
City
POPE AFB
State
NC
ZIP
28308
Mailing
1617 GILLESPIE STREET, FAYETTEVILLE, NC 28306
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.404 F06

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 26, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous:    Pope Army Airfield Bldg. 308 Renovation:  A green 100ft power cord and a yellow GFCI cord had missing ground pins.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.405 G02 IV

Other-than-serious 2 instances 3 exposed
Issued
Sep 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  Pope Army Airfield Bldg. 308 Renovation:  A green 100ft power cord and a wet/dry vac equipment cord lacked proper strain relief thereby exposing internal wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View L & L Drywall & Construction CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339420424.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.