STROUDSBURG, PA ·
OSHA Inspection: STRUNK TREE SERVICE, INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STRUNK TREE SERVICE, INCORPORATED in 103 PARKWAY DRIVE, STROUDSBURG, PA 18360 (NAICS 561730). OSHA activity number 339421240.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STRUNK TREE SERVICE, INCORPORATED
- Site address
- 103 PARKWAY DRIVE
- City
- STROUDSBURG
- State
- PA
- ZIP
- 18360
- Mailing
- 2020 HANEY ROAD, STROUDSBURG, PA 18360
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.332 B01
- Issued
- Nov 18, 2013
- Abate by
- Dec 13, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a) 103 Parkway Drive, Stroudsburg, PA; Employees working near live power lines while performing tree trimming services were not trained to maintain a distance of 10 feet, on or about 09/12/2013. Abatement Certification and Documentation Required
Recent events (1)
- · Z (S) $2800
1910.333 C03 I A
- Issued
- Nov 18, 2013
- Abate by
- Dec 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(3)(i)(A): When an unqualified person is working in an elevated position near overhead lines, the location was not such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances: a) 103 Parkway Drive, Stroudsburg, PA; While an employee was operating a Stihl power sheer used to trim hedges, the employee struck an uninsulated live power line which contained 34,500 volts of electricity, on or about 09/12/2013. Abatement Certification and Documentation Required
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 561730)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339421240.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.