Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PARK GROUP, LLC in 610 AGNES DR., BREAUX BRIDGE, LA 70517 (NAICS 236220). OSHA activity number 339421760.

Watch Park Group, LLC — free Get an email when a new federal OSHA severe-injury report for Park Group, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PARK GROUP, LLC
Site address
610 AGNES DR.
City
BREAUX BRIDGE
State
LA
ZIP
70517
Mailing
326 SETTLERS TRACE BLVD, SUITE 100B, LAFAYETTE, LA 70508
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
12
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.  On or about 09/19/2013, at the Garden Park Resiential Housing construction site, lot#1-6, the employer failed to provide eye protection for the employees who were using pneumatic nail guns and circular saws.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.404 B01 II

Serious Gravity 5 2 instances 12 exposed
Issued
Penalty
Initial $1700.00 · Current $1020.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.  On or about 09/19/2013, at Garden Park Residential Housing Construction site, lot #1-6 the employer failed to ensure that ground fault circuit interrupters (GFCIs) were in place prior to allowing the employees to operate electrical tools.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1926.416 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: to provide to portable electrical equipment at the construction site.  On or about 09/19/2013, at the Garden Park Residential Housing construction sight, lots #1-6 the employer failed to provide electrical cords that were not frayed or damaged.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1020.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   On or about 09/19/2013, at the Garden Park Residential Housing construction site, lots #1-6 the employer failed to ensure that adequate fall protection was worn by the employees working on the roofs at an elevation of 18-25 ft.