Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CURBS PLUS INC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CURBS PLUS INC in 8767 GA HWY 151, RINGGOLD, GA 30736 (NAICS 332322). OSHA activity number 339422776.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Curbs Plus INC — free Get an email when a new federal OSHA severe-injury report for Curbs Plus INC is published. One employer, no account, unsubscribe in one click.
Establishment
CURBS PLUS INC
Site address
8767 GA HWY 151
City
RINGGOLD
State
GA
ZIP
30736
Mailing
8767 GA HWY 151, RINGGOLD, GA 30736
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
89
Ownership type
A

7 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 22, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced

Hazardous substances 2590

29 CFR 1910.107(b)(5)(i): The employer did not have visible guages, audible alarms, or pressure activated devices installed to indicate or ensure that he required air velocity was maintained on a spray booth:    a) Spray Paint Room #1 and #2: The employer failed to ensure that an air velocity meter, audible alarm or other means were available to warn personnel when there was a decrease in air velocity in the the spray rooms. Employees were exposed to the hazards of a fire and/or explosion while utilizing flammable materials such as, but not limited to, Sherwin Williams Chem 4000, Sherwin Williams Quick Dry that contained acetone, toluene, xylene, mineral spirits and other highly flammable materials while spray painting fabricated metal components used in the manufacture of HVAC roof curbs.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.107 B05 IV

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 22, 2014
Abate by
Mar 31, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced

Hazardous substances 2590

29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    a) Spray Paint Room #1 and #2: The employer failed to ensure that an automatic sprinkler system was maintained in the interior of the spray paint rooms. Employees were exposed to the hazards of a fire and/or explosion while utilizing acetone, xylene, toluene and other highly flammable materials to spray painting fabricated metal components used in the manufacture of HVAC roof curbs.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.107 D03

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 22, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced

Hazardous substances 2590

29 CFR 1910.107(d)(3): Independent exhaust. Each spray booth shall have an independent exhaust duct system discharging to the exterior of the building, except that multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than 18 square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without all fans being operated.     a) Spray Paint Room #1 and #2: The employer failed to ensure that an exhaust duct system was maintained on the spray rooms to facilitate the movement of flammable vapors and/or residue to the exterior of the building. Employees were exposed to the hazards of a fire and/or explosion while utilizing acetone, xylene, toluene and other highly flammable materials to spray paint fabricated metal components used in the manufacture of HVAC roof curbs.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.151 C

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 22, 2014
Penalty
Initial $4,200 · Current $2,100 Reduced

Hazardous substances 2085

29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.       a) Spray Paint Prep Area: The employer failed to ensure that an eyewash/shower facility was available and operational for employees that utilized and handled injurious materials such as, but not limited to, Clean 'N Etch (phosphoric acid). Employees were exposed to the material while performing operator assigned duties involving the cleaning of fabricated metal components.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1910.134 E01

Other-than-serious 1 instance 4 exposed
Issued
Jan 22, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:   a) Spray Paint Room: The employer failed to ensure that medical evaluations were provided for users of a 3M one half mask respirator (6200). Employees were exposed to materials such as, but not limited to, toluene, acetone, xylene, and other hazardous materials while performing assigned duties involving maintenance, spray painting operations and other duties for the manufacture of metal HVAC roof curbs.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F01

Other-than-serious 1 instance 4 exposed
Issued
Jan 22, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph:    a) Spray Paint Room: The employer failed to provide annual fit test for users of a 3M one half mask respirator (6200). Employees were exposed to materials such as, but not limited to, toluene, acetone, xylene, and other hazardous materials while performing assigned duties involving maintenance, spray painting operations and other duties for the manufacture of metal HVAC roof curbs.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K

Other-than-serious 1 instance 4 exposed
Issued
Jan 22, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.134(k): The employer did not provided effective training to employees who are required to use respirators:    a) Spray Paint Room: The employer failed to provide training and information on respiratory protection for employees exposed to materials such as, but not limited to, toluene, acetone, xylene, and other hazardous materials while performing assigned duties involving the manufacture of fabricated metal HVAC roof curbs. Employees were required to utilize a 3M one half mask respirator (6200).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Curbs Plus INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339422776.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.