RINGGOLD, GA —
OSHA Inspection: CURBS PLUS INC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of CURBS PLUS INC in 8767 GA HWY 151, RINGGOLD, GA 30736 (NAICS 332322). OSHA activity number 339422776.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CURBS PLUS INC
- Site address
- 8767 GA HWY 151
- City
- RINGGOLD
- State
- GA
- ZIP
- 30736
- Mailing
- 8767 GA HWY 151, RINGGOLD, GA 30736
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 89
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.107 B05 I
- Issued
- Jan 22, 2014
- Penalty
- Initial $4,900 · Current $2,450 Reduced
2590
General-duty citation text
29 CFR 1910.107(b)(5)(i): The employer did not have visible guages, audible alarms, or pressure activated devices installed to indicate or ensure that he required air velocity was maintained on a spray booth: a) Spray Paint Room #1 and #2: The employer failed to ensure that an air velocity meter, audible alarm or other means were available to warn personnel when there was a decrease in air velocity in the the spray rooms. Employees were exposed to the hazards of a fire and/or explosion while utilizing flammable materials such as, but not limited to, Sherwin Williams Chem 4000, Sherwin Williams Quick Dry that contained acetone, toluene, xylene, mineral spirits and other highly flammable materials while spray painting fabricated metal components used in the manufacture of HVAC roof curbs.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.107 B05 IV
- Issued
- Jan 22, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $4,900 · Current $2,450 Reduced
2590
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) Spray Paint Room #1 and #2: The employer failed to ensure that an automatic sprinkler system was maintained in the interior of the spray paint rooms. Employees were exposed to the hazards of a fire and/or explosion while utilizing acetone, xylene, toluene and other highly flammable materials to spray painting fabricated metal components used in the manufacture of HVAC roof curbs.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.107 D03
- Issued
- Jan 22, 2014
- Penalty
- Initial $4,900 · Current $2,450 Reduced
2590
General-duty citation text
29 CFR 1910.107(d)(3): Independent exhaust. Each spray booth shall have an independent exhaust duct system discharging to the exterior of the building, except that multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than 18 square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without all fans being operated. a) Spray Paint Room #1 and #2: The employer failed to ensure that an exhaust duct system was maintained on the spray rooms to facilitate the movement of flammable vapors and/or residue to the exterior of the building. Employees were exposed to the hazards of a fire and/or explosion while utilizing acetone, xylene, toluene and other highly flammable materials to spray paint fabricated metal components used in the manufacture of HVAC roof curbs.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.151 C
- Issued
- Jan 22, 2014
- Penalty
- Initial $4,200 · Current $2,100 Reduced
2085
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use. a) Spray Paint Prep Area: The employer failed to ensure that an eyewash/shower facility was available and operational for employees that utilized and handled injurious materials such as, but not limited to, Clean 'N Etch (phosphoric acid). Employees were exposed to the material while performing operator assigned duties involving the cleaning of fabricated metal components.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1910.134 E01
- Issued
- Jan 22, 2014
- Penalty
- Initial $0 · Current $0
2590
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace: a) Spray Paint Room: The employer failed to ensure that medical evaluations were provided for users of a 3M one half mask respirator (6200). Employees were exposed to materials such as, but not limited to, toluene, acetone, xylene, and other hazardous materials while performing assigned duties involving maintenance, spray painting operations and other duties for the manufacture of metal HVAC roof curbs.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F01
- Issued
- Jan 22, 2014
- Penalty
- Initial $0 · Current $0
2590
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: a) Spray Paint Room: The employer failed to provide annual fit test for users of a 3M one half mask respirator (6200). Employees were exposed to materials such as, but not limited to, toluene, acetone, xylene, and other hazardous materials while performing assigned duties involving maintenance, spray painting operations and other duties for the manufacture of metal HVAC roof curbs.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K
- Issued
- Jan 22, 2014
- Penalty
- Initial $0 · Current $0
2590
General-duty citation text
29 CFR 1910.134(k): The employer did not provided effective training to employees who are required to use respirators: a) Spray Paint Room: The employer failed to provide training and information on respiratory protection for employees exposed to materials such as, but not limited to, toluene, acetone, xylene, and other hazardous materials while performing assigned duties involving the manufacture of fabricated metal HVAC roof curbs. Employees were required to utilize a 3M one half mask respirator (6200).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Curbs Plus INC
View Curbs Plus INC's full OSHA safety record →
More inspections in this industry (NAICS 332322)