OSHA Inspection: A.D. SIDING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A.D. SIDING in CLUBHOUSE CROSSING LOT 195, ACWORTH, GA 30101 (NAICS 238170). OSHA activity number 339423675.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A.D. Siding for free Get an email when a new federal OSHA severe-injury report for A.D. Siding is published. One employer, no account, unsubscribe in one click.
Establishment
A.D. SIDING
Site address
CLUBHOUSE CROSSING LOT 195
City
ACWORTH
State
GA
ZIP
30101
Mailing
66 NORTHWOOD DR, ATLANTA, GA 30342
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 23, 2014
Abate by
Jan 29, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.   a) Lot 195 Clubhouse Crossing Acworth GA back scaffold: An employee was exposed to collapse hazards while working 16 feet above ground level from pump jack scaffolding that did not bare on base plates and mud sills or other adequate firm foundation
Recent events (1)
  • · Z (S) $2000

1926.452 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 23, 2014
Abate by
Jan 29, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.   a. Lot 195 Clubhouse Crossing Acworth GA back scaffold: An employee was exposed to collapse hazards while working 16 feet above ground level from pump jack scaffolding that was not secured on the bottom.
Recent events (1)
  • · Z (S) $2000

1926.452 J03

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 23, 2014
Abate by
Jan 29, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.452(j)(3): When guardrails are used for fall protection, a workbench may be used as the toprail only if it meets all the requirements in paragraphs (g)(4)(ii), (vii), (viii), and (xiii) of 1926.451.   a) Lot 195 Clubhouse Crossing Acworth GA back scaffold: An employee was exposed to fall hazards while working 16 feet above ground level from pump jack scaffolding without mid or end rails.