JERSEY CITY, NJ —
OSHA Inspection: PACIFIC GENERAL CONTRACTOR LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PACIFIC GENERAL CONTRACTOR LLC in 260 FIRST STREET, JERSEY CITY, NJ 07304 (NAICS 236220). OSHA activity number 339424624.
Where did this inspection happen?
- Establishment
- PACIFIC GENERAL CONTRACTOR LLC
- Site address
- 260 FIRST STREET
- City
- JERSEY CITY
- State
- NJ
- ZIP
- 07304
- Mailing
- 697 KEARNY AVE, KEARNY, NJ 07032
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: a. 260 First Street Jersey City, NJ Employees were observed performing siding activities from a welded tubular frame scaffold that was not fully planked between the front uprights and the guardrail supports, thereby exposing employees to 36 ft fall hazards. Violation observed on or about 07/31/2013
Recent events (1)
- — Z (S) $2800
1926.451 C02
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a. 260 First Street Jersey City, NJ - South side of the building Employees were conducting work from a supported scaffold. Some of the supported scaffold posts were not resting on base plates. b. 260 First Street Jersey City, NJ South side of the building Employees were conducting work from a supported scaffold. Some of the supported scaffold posts were not resting on mudsills. Violation observed on or about 06/17/2013
Recent events (1)
- — Z (S) $2800
1926.451 E01
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. 260 First Street Jersey City, NJ Safe access and egress to the welded tubular frame scaffold was not provided to the work platform. Employees were observed egressing a welded tubular frame scaffold work platform using the cross braces. Violation observed on or about 07/31/2013
Recent events (1)
- — Z (S) $2800
1926.451 G01
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: 260 First Street Jersey City, NJ Employee(s) were observed working from a welded tubular frame scaffold approximately 36 feet from the ground below without utilizing any type of fall protection, exposing the employees to fall hazards. Violation observed on or about 07/31/2013
Recent events (1)
- — Z (S) $2800
1926.452 C02
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a. 260 First Street Jersey City, NJ Employees were observed performing siding activities from a four tier, welded tubular frame scaffold that was not cross braced on the inside, which would have secured and squared the vertical members laterally. Violation observed on or about 07/31/2013
Recent events (1)
- — Z (S) $2800
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC
FREEHOLD, NJ—2026-07-10
VACCA ROOFING
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
FREEHOLD, NJ—2026-07-10
GTN CONSTRUCTION INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339424624.