Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: ATRIAN CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ATRIAN CONSTRUCTION in 2445 ANDERSON ESTATES COURT, MARIETTA, GA 30064 (NAICS 238170). OSHA activity number 339424939.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atrian Construction for free Get an email when a new federal OSHA severe-injury report for Atrian Construction is published. One employer, no account, unsubscribe in one click.
Establishment
ATRIAN CONSTRUCTION
Site address
2445 ANDERSON ESTATES COURT
City
MARIETTA
State
GA
ZIP
30064
Mailing
877 JAMES ROAD, LAWRENCEVILLE, GA 30044
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 3, 2014
Abate by
Feb 13, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  (a) On the west side of the residence, employees working from a pump jack scaffold installing siding on a two-story residence were not provided with fall protection, the employees were exposed to a fall of more than 17 feet to the next lower level.
Recent events (1)
  • · Z (S) $3080

1926.452 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 3, 2014
Abate by
Feb 13, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:  (a) On the west side of the residence, the employer allowed employees to work from a pump jack scaffold that did not have the bottom secured by rigid triangular bracing or equivalent means to prevent displacement, exposing the employees to a fall of more than 17 feet to the next lower level.
Recent events (1)
  • · Z (S) $3080

1926.454 A

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 3, 2014
Abate by
Feb 28, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  (a) On the west side of the residence, employees installing siding from a pump jack scaffold were not trained to recognize the hazards associated with the use of a pump jack scaffold and the methods to control and minimize the hazards. The employees were exposed to a fall hazard of more than 17 feet.
Recent events (1)
  • · Z (S) $3080

View Atrian Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339424939.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.