Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KIRCHOFF CONSIGLI-CONSTRUCTION MANAGEMENT, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of KIRCHOFF CONSIGLI-CONSTRUCTION MANAGEMENT, LLC in 1400 WASHINGTON AVE., ALBANY, NY 12222 (NAICS 236220). OSHA activity number 339424988.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kirchoff Consigli-Construction Management, LLC — free Get an email when a new federal OSHA severe-injury report for Kirchoff Consigli-Construction Management, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1400 WASHINGTON AVE.
City
ALBANY
State
NY
ZIP
12222
Mailing
199 WEST RD. SUITE 100, PLEASANT VALLEY, NY 12569
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
106
Ownership type
A

4 citations on file for this inspection.

1926.95 A

Deleted Other-than-serious 1 instance 1 exposed
Issued
Nov 29, 2013
Abate by
Dec 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.  a) Jobsite, University at Albany Business Administration Center- On or about 09/24/13- Punch List Supervisor cutting wooden hand railing was not wearing protective eye wear and exposed to eye injury struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.102 A02

Deleted Other-than-serious 1 instance 1 exposed
Issued
Nov 29, 2013
Abate by
Dec 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.102(a)(2): Eye and face protection required by this Part did not meet the requirements specified in American National Standards Institute, Z87.1-1968, Practice for Occupational and Educational Eye and Face Protection:   a) Jobsite, University at Albany Business Administration Center- On or about 09/24/13- Laborer cutting wooden hand railing was wearing standard sunglasses and exposed to eye injury struck-by hazards .
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.404 B01 I

Deleted Other-than-serious 1 instance 2 exposed
Issued
Nov 29, 2013
Abate by
Dec 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  a) Jobsite, University at Albany Business Administration Center- On or about 09/24/13- Employees using a 115v electrical operated Hitachi KoKi sliding compound miter saw not equipped with ground fault circuit protection were exposed to an electrical shock hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 A02 II I

Deleted Other-than-serious 1 instance 2 exposed
Issued
Nov 29, 2013
Abate by
Dec 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:  a) Jobsite, University at Albany Business Administration Center- On or about 09/24/13- Temporary flexible electrical lead cord used to power a 115v Hitachi KoKi sliding compound miter saw was passed through a doorway and pinched under a propped open doorway.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kirchoff Consigli-Construction Management, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339424988.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.