Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STONE CREEK MASONRY LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STONE CREEK MASONRY LLC in 4472 STERLING POINTE DRIVE, KENNESAW, GA 30152 (NAICS 238140). OSHA activity number 339425449.

Watch Stone Creek Masonry LLC — free Get an email when a new federal OSHA severe-injury report for Stone Creek Masonry LLC is published. One employer, no account, unsubscribe in one click.
Site address
4472 STERLING POINTE DRIVE
City
KENNESAW
State
GA
ZIP
30152
Mailing
1506 CHASEWAY CIRCLE, POWDER SPRINGS, GA 30127
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:     (a) 4472 Sterling Point Drive, Kennesaw, front of the residence: The employer did not provide a safe means of access for employees using a tubular welded frame scaffold system to install brick veneer on a 2-story residence. The employees were climbing the prefabricated end frame of the scaffold. Employees were exposed to a fall hazard of approximately 13-feet, 10-inches, to the next lower level.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1926.451 G01 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    (a) 4472 Sterling Point Drive, Kennesaw, Front of the residence: Employees observed installing brick veneer from a tubular welded frame scaffold system were not protected from falling by the use of personal fall arrest system or guardrails. The employees were exposed to a fall hazard of approximately 13-feet, 10-inches, to the next lower level.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1926.452 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:    (a) 4472 Sterling Point Drive, Kennesaw, Front of the residence: Employees were observed installing brick veneer from a tubular welded frame scaffold system where cross braces were installed only on certain portions of the scaffold system, exposing the employees to a fall hazard of approximately 13-feet, 10-inches, to the next lower level.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339425449.