Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: ALICE-SIDNEY DRYER & SEED CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ALICE-SIDNEY DRYER & SEED CO. in 2543 HWY. 165 SOUTH, DERMOTT, AR 71638 (NAICS 115114). OSHA activity number 339427007.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alice-Sidney Dryer & Seed CO. for free Get an email when a new federal OSHA severe-injury report for Alice-Sidney Dryer & Seed CO. is published. One employer, no account, unsubscribe in one click.
Site address
2543 HWY. 165 SOUTH
City
DERMOTT
State
AR
ZIP
71638
Mailing
2543 HWY. 165 SOUTH, DERMOTT, AR 71638
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115114
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 5, 2013
Abate by
Nov 29, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.  On or about September 25, 2013 and times prior thereto employees were exposed to fall heights of approximately 50 feet.  To access the top of bin #23 employees climb over an obstruction on the catwalk.  While climbing the obstruction the employee is above the guard rail.
Recent events (1)
  • · Z (S) $2000

1910.68 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 5, 2013
Abate by
Dec 6, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.68(e)(1): All manlifts were not inspected by a designated competent person at intervals of not more than 30 days:  On September 25, 2013 and times prior thereto the employer did not have its man lift inspected at least every 30 days by a competent person.
Recent events (1)
  • · Z (S) $2000

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 5, 2013
Abate by
Nov 14, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  On or about September 25, 2013 and times prior thereto employees were exposed to the pinch points created by an unguarded belt and pulley by the drive motor for the dump conveyors.
Recent events (1)
  • · Z (S) $2000

1910.303 G01 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 5, 2013
Abate by
Nov 14, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:     On or about September 25, 2013 and times prior thereto the area in front of the electrical starters and breakers for the product conveyors was obstructed by the parking of vehicle.  The depth of the working space was approximately 27 inches where 36 inches are required to provide safe access.
Recent events (1)
  • · Z (S) $2000

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 5, 2013
Abate by
Nov 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  On or about September 25, 2013 and times prior thereto, employees were exposed to the hazards of electrical shock from the exposed conductors of the conveyor starters and breakers where the front covers had been removed.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339427007.