OSHA Inspection: C&D ROOFING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C&D ROOFING in 7763 OLD SPEC ROAD, PEYTON, CO 80831 (NAICS 238160). OSHA activity number 339427957.

Watch C&D Roofing — free Get an email when a new federal OSHA severe-injury report for C&D Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
C&D ROOFING
Site address
7763 OLD SPEC ROAD
City
PEYTON
State
CO
ZIP
80831
Mailing
1685 S. COLORADO BLVD. S-310, DENVER, CO 80222
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    (a) On or about September 26, 2013, the employer did not ensure that employees working on the ground below roofing activites were protected from overhead falling objectes by ensuring that they wore hard hats.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  (a) On or about September 26, 2013, the employer did not ensure that employees using pneumatic nail guns were protected from eye injury by ensuring that they wore safety glasses.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.300 B03

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.300(b)(3): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a)  On or about September 26, 2013, the employer did not ensure employees were safe from rotating parts and nip points on the compressor for the pneumatic nail guns that has a belt and pulley system that was not guarded.      Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     (a)  On or about September 26, 2013, the employer did not ensure employees were protected from fall hazards of greater than 9 feet while reroofing a house without fall protection.      Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:    (a) On or about September 26, 2013, the employer did not protect employees from fall hazards from a ladder used as access the roof that did not extend three feet above the landing surface and was not secured at the top.      Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

View C&D ROOFING's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339427957.