OSHA Inspection: FRUTH PHARMACY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FRUTH PHARMACY in 120 WEST 2ND STREET, WELLSTON, OH 45692 (NAICS 446110). OSHA activity number 339429524.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fruth Pharmacy for free Get an email when a new federal OSHA severe-injury report for Fruth Pharmacy is published. One employer, no account, unsubscribe in one click.
Establishment
FRUTH PHARMACY
Site address
120 WEST 2ND STREET
City
WELLSTON
State
OH
ZIP
45692
Mailing
120 WEST 2ND STREET, WELLSTON, OH 45692
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
446110
Employees
21
Ownership type
A

6 citations on file for this inspection.

1910.22 B01

Serious Gravity 5 2 instances 21 exposed
Issued
Oct 15, 2013
Abate by
Nov 5, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.22(b)(1): Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repairs, with no obstruction across or in aisles that could create a hazard.     a)     On or about October 03, 2013, in the rear storage area, center of the floor, the employer did not ensure that a circular (in diameter) piece of pertruding steel in the floor was covered or removed, thereby exposing employees to a potential trip/fall hazard.  b)     On or about October 03, 2013, in the front/side area of the store, by the greeting cards, the employer did not ensure that floor did not have a raise crack across the floor asile, thereby exposing employees to a potential trip/fall hazard.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $1600

1910.22 D01

Serious Gravity 1 2 instances 3 exposed
Issued
Oct 15, 2013
Abate by
Nov 5, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent.     a)     On or about October 03, 2013, in the rear of store area, the employer did not ensure that the managers office space, which had boxes of material stored above, was equipped with a load limit plate, thereby exposing employees to a potential struck-by hazard.  b)     On or about october 03, 2013, in the rear of store area, the employer did not ensure that the receivers office space, which had boxes of material stored above, was equipped with a load limit plate, thereby exposing employees to a potential struck-by hazard.
Recent events (2)
  • · I (S) $840
  • · Z (S) $1200

1910.303 G01

Serious Gravity 1 1 instance 21 exposed
Issued
Oct 15, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.     a)     On or about October 03, 2013, in the first flloor rear stockroom area, the employer did not ensure that the energized electrical panel box number P-157 was not blocked and had enough room to work on in case of an emergency, thereby exposing employees to a potential burn hazard.
Recent events (2)
  • · I (S) $840
  • · Z (S) $1200

1910.305 D02

Serious Gravity 10 3 instances 3 exposed
Issued
Oct 15, 2013
Abate by
Oct 22, 2013
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.     a)     On or about October 03, 2013, in the rear, first floor storage area, by the rear door exit, the energized electrical panal (Box 101) had a missing circuit breaker on the front of the electrical panel, thereby exposing employees to an electrocution hazard.  b)     On or about October 03, 2013, in the rear, first floor storage area, electrical panel number P-157 had missing circuit breakers on the front of the electrical panel, thereby exposing employees to an electrocution hazard.  c)     On or about October 03, 2013, in the rear, first floor storage area, electrical panel number P-158 had missing circuit breakers on the front of the electrical panel, thereby exposing employees to an electrocution hazard.
Recent events (2)
  • · I (S) $1960
  • · Z (S) $2800

1910.303 E01

Serious Gravity 5 3 instances 2 exposed
Issued
Oct 15, 2013
Abate by
Oct 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1): Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment:  29 CFR 1910.303(e)(1)(ii): Other markings giving voltage, current, wattage, or other ratings as necessary.     a)     On or about October 03, 2013, in the rear storage room area, by the rear exit door, the energized electrical panel box number 101 was not marked to identify at least voltage.  b)     On or about October 03, 2013, in the rear storage room area, the energized electrical panel box number P-157 was not marked to identify at least voltage.  c)     On or about October 03, 2013, in the rear storage room area, the energized electrical panel box number P-158 was not marked to identify at least voltage.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G02 I

Serious Gravity 5 3 instances 2 exposed
Issued
Oct 15, 2013
Abate by
Oct 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:     a)     On or about October 03, 2013, in the rear storage room area, by the rear exit door, the energized electrical panel box number 101 had an unused opening, due to a missing breaker, thereby exposing employees to a potential shock hazard.  b)     On or about October 03, 2013, in the rear storage room area, the energized electrical panel box number P-157 had unused openings, due to missing breakers, thereby exposing employees to a potential shock hazard.  c)     On or about October 03, 2013, in the rear storage room area, the energized electrical panel box number P-158 had unused openings, due to missing breakers, thereby exposing employees to a potential shock hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339429524.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.