Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARBER CONSTRUTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARBER CONSTRUTION LLC in 994 OCEAN BLVD, HAMPTON, NH 03843 (NAICS 238160). OSHA activity number 339429912.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harber Constrution LLC — free Get an email when a new federal OSHA severe-injury report for Harber Constrution LLC is published. One employer, no account, unsubscribe in one click.
Site address
994 OCEAN BLVD
City
HAMPTON
State
NH
ZIP
03843
Mailing
P.O. BOX 905, EPSOM, NH 03234
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 25, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:         (a) Roof - Employees were using pnuematic nail guns without safety glasses.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 25, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used:    (a) Jobsite - Employees were exposed to an 18 foot fall while no ladder was supplied for access to the ladder-jack scaffolding.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 25, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:    (a) Roof - Employees were exposed to an 18 foot fall hazard while working from a ladder-jack scaffolding without the use of fall protection.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339429912.