CONNEAUT, OH —
OSHA Inspection: GENERAL ALUMINUM MFG. CO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GENERAL ALUMINUM MFG. CO in 1370 CHAMBERLAIN BLVD., CONNEAUT, OH 44030 (NAICS 331524). OSHA activity number 339430175.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENERAL ALUMINUM MFG. CO
- Site address
- 1370 CHAMBERLAIN BLVD.
- City
- CONNEAUT
- State
- OH
- ZIP
- 44030
- Mailing
- 1370 CHAMBERLAIN BLVD., CONNEAUT, OH 44030
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331524
- Employees
- 314
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A03 II
- Issued
- Feb 13, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On and before 10/04/2013, rear of the #3Tilt-Pour Mold on the 580 table, located in the Molding department, was not equipped with guarding to prevent operators from having access to the tilting device during normal production.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.147 D03
- Issued
- Feb 13, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $70,000 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about 09/07/2013 the electrical energy, and the hydraulic pressure for the #3 Tilt-Pour Mold on the 580 table, were not isolated during mold cleaning operations.
Recent events (3)
- — F (S) $7000
- — C (W) $70000
- — Z (W) $70000
1910.147 D04 I
- Issued
- Feb 13, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On and before 10/04/2014, the #3 Tilt-Pour Mold on the 580 line, was not locked out during mold cleaning operations. Potentially hazardous energy sources include the following: electricity, hydraulic energy, thermal energy, and gravity.
Recent events (3)
- — F (S) $0
- — C (W) $0
- — Z (W) $0
More inspections at General Aluminum MFG. CO
View General Aluminum MFG. CO's full OSHA safety record →
More inspections in this industry (NAICS 331524)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339430175.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.