Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: STINGER, LTD

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STINGER, LTD in 8905 INDUSTRIAL DRIVE, HAVEN, KS 67543 (NAICS 333111). OSHA activity number 339430233.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stinger, LTD for free Get an email when a new federal OSHA severe-injury report for Stinger, LTD is published. One employer, no account, unsubscribe in one click.
Establishment
STINGER, LTD
Site address
8905 INDUSTRIAL DRIVE
City
HAVEN
State
KS
ZIP
67543
Mailing
8905 INDUSTRIAL DRIVE, HAVEN, KS 67543
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333111
Employees
29
Ownership type
Private (A)

2 citations on file for this inspection.

1910.252 B02 III

Serious Gravity 1 1 instance 29 exposed
Issued
Nov 6, 2013
Abate by
Jan 14, 2014
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  On the shop floor, employees walking in the building are not protected from welding rays in that welding curtains are not positioned to block them, exposing employees to eye injury.
Recent events (2)
  • · I (S) $1249.5
  • · Z (S) $1785

1910.305 B01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 6, 2013
Abate by
Jan 14, 2014
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  On the shop floor, the electrical outlet box (110 VAC), which powered the Jet sander was missing a knockout, exposing employees to an electrical shock.
Recent events (2)
  • · I (S) $1249.5
  • · Z (S) $1785

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339430233.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.