Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: INDUSTRIAL CONSTRUCTION SERVICES AND DESIGN, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of INDUSTRIAL CONSTRUCTION SERVICES AND DESIGN, INC. in 10 S. GROSSMAN ROAD, STOWE, PA 19464 (NAICS 238990). OSHA activity number 339431710.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Industrial Construction Services and Design, INC. — free Get an email when a new federal OSHA severe-injury report for Industrial Construction Services and Design, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10 S. GROSSMAN ROAD
City
STOWE
State
PA
ZIP
19464
Mailing
PO BOX 175, LAKE WINOLA, PA 18625
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
12
Ownership type
A

10 citations on file for this inspection.

1926.62 C01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 7, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 15911592

29 CFR 1926.62(c)(1): The employer did not ensure that no employees were exposed to lead at concentrations greater than fifty micro-grams per cubic meter of air (50 ug/m3) averaged over an 8-hour period:     a. Hammond Lead Site - On or about October 17, 2013, An employee, welder, who was welding on structural steel during the installation of a new ventilation was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  The level is 2.16 times the Permissible Exposure Limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling.  A zero exposure was assumed for the 60 minutes not sampled.   No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1926.62 E01

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2014
Penalty
Initial $0 · Current $3,500

Hazardous substances 15911592

29 CFR 1926.62(e)(1): The employer did not implement all feasible engineering and work practice controls, including administrative controls, to reduce and maintain employee exposure to lead to or below the permissible exposure limit:     a.   On or about October 17, 2013, an employee, welder, who was welding on structural steel during the installation of a new ventilation system was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  This level is 2.16 times the permissible exposure limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling period.  A zero exposure was assumed for the 60 minutes not sampled.       Feasible abatement methods include but are not limited to:    1.)  Provided localized exhaust ventilation to remove welding fume during the welding operation.  2.) Remove lead contamination or lead paint prior to conducting any welding operations.     No abatement certification or documentation required.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $0

1926.62 F02 I

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 15911592

29 CFR 1926.62(f)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m) for each employee required by 29 CFR 1926.62 to use a respirator:     a. Hammond Lead Site - On or about October 17, 2013, an employee, welder, who was welding on structural steel during the installation of a new ventilation system was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  This level is 2.16 times the permissible exposure limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling period.  A zero exposure was assumed for the 60 minutes not sampled
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 15911592

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting face piece respirators were not fit tested prior to initial use of the respirator:      a. Hammond Lead Site - On or about October 17, 2013, an employee, welder, who was welding on structural steel during the installation of a new ventilation system was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  This level is 2.16 times the permissible exposure limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling period.  A zero exposure was assumed for the 60 minutes not sampled  The employer did not provide respirator fit testing for employee required to wear 3M 8293 or Moldex 2730 negative pressure respirators who was exposed to the hazards of lead in excess of the Permissible Exposure Limit (PEL).     Note: 29 CFR 1926.62(f)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m) for each employee required by 29 CFR 1926.62 to use a respirator.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 H02 I

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 15911592

29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the face piece and exhalation valve:        a.  On or about October 17, 2013, an employee, welder, who was welding on structural steel during the installation of a new ventilation system was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  This level is 2.16 times the permissible exposure limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling period.  A zero exposure was assumed for the 60 minutes not sampled  The employees did not properly store respirators when not in use, by placing them on lead contaminated surfaces.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 K01

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 15911592

29 CFR 1910.134(k): Training and information.  The employer did not provide effective training to employees who are required to use respirators:    a. Hammond Lead Site -  On or about October 17, 2013, an employee, welder, who was welding on structural steel during the installation of a new ventilation system was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  This level is 2.16 times the permissible exposure limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling period.  A zero exposure was assumed for the 60 minutes not sampled.  The employer did not provide respirator training for employee required to wear 3M8293 or Moldex 2730 negative pressure respirators, who was exposed to the hazards of lead in excess of the Permissible Exposure Limit (PEL).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.62 E02 I

Other-than-serious 1 instance 3 exposed
Issued
Feb 7, 2014
Penalty
Initial $3,500 · Current $3,500

Hazardous substances 15911592

29 CFR 1926.62(e)(2)(i): The employer did not establish and implement a written compliance program to achieve compliance with 29 CFR 1926.62(c) prior to commencement of the job:     a. Hammond Lead Plant - On or about October 17, 2013, The employer did not establish and implement a written compliance program which included the following for employees exposed to the hazards of lead:          - A description of each activity in which lead is emitted; e.g. equipment used, material involved, controls in place, crew size, employee job responsibilities, operating procedures and maintenance practices;1926.62(e)(2)(ii)(B).   - A description of the specific means that will be employed to achieve compliance and, where engineering controls. are required engineering plans and studies used to determine methods selected for controlling exposure to lead;1926.62(e)(2)(ii)(C).   - A report of the technology considered in meeting the PEL;1926.62(e)(2)(ii)(D) Air monitoring data which documents the source of lead emissions;1926.62(e)(2)(ii)(E).    - A detailed schedule for implementation of the program, including documentation such as copies of purchase orders for equipment, construction contracts, etc.;1926.62(e)(2)(ii)(F).    - A work practice program which includes items required under paragraphs (g), (h) and (i) of this section and incorporates other relevant work practices such as those specified in paragraph (e)(5) of this section;1926.62(e)(2)(ii)(G).    - An administrative control schedule required by paragraph (e)(4) of this section, if applicable;1926.62(e)(2)(ii)(H).    - A description of arrangements made among contractors on multi-contractor sites with respect to informing affected employees of potential exposure to lead and with respect to responsibility for compliance with this section as set-forth in 1926.16.1926.62(e)(2)(ii)(I).       NOTE: The compliance program shall provide for frequent and regular inspections of job sites, materials, and equipment to be made by a competent person.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $3500

1926.62 D01 I

Other-than-serious 3 instances 3 exposed
Issued
Feb 7, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 15911592

29 CFR 1926.62(d)(1)(i): Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level of 30 micro-grams per cubic meter of air calculated as an 8-hour time-weighted average (TWA):      a.  On or about October 17, 2013, an employee, welder, who was welding on structural steel during the installation of a new ventilation system was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  This level is 2.16 times the permissible exposure limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling period.  A zero exposure was assumed for the 60 minutes not sampled.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.62 L01 II

Other-than-serious 2 instances 2 exposed
Issued
Feb 7, 2014
Penalty
Initial $3,500 · Current $3,500

Hazardous substances 15911592

29 CFR 1926.62(l)(1)(ii): The employer did not train each employee who were subject to exposure to lead at or above the action level on any day, or who were subject to exposure to lead compounds which may cause skin or eye irritation (e.g., lead arsenate, lead azide) in accordance with the requirements of 29 CFR 1926.62 and the employer did not institute a training program and ensure employee participation in the program:     a. Hammond Lead Plant -  On or about October 17, 2013, an employee, welder, who was welding on structural steel during the installation of a new ventilation system was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  This level is 2.16 times the permissible exposure limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling period.  A zero exposure was assumed for the 60 minutes not sampled.  The employer did not provide a training program in accordance with paragraph (l)(2) of this section, for employees exposed to the hazards of lead while working on lead contaminated structural steel.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $3500

1926.62 J01 I

Other-than-serious 3 instances 3 exposed
Issued
Feb 7, 2014
Abate by
Mar 14, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 15911592

29 CFR 1926.62(j)(1)(i): The employer did not make available initial medical surveillance, consisting of biological monitoring in the form of blood sampling and analysis for lead and zinc protoporphyrin levels, to employees occupationally exposed on any day to lead at or above the action level:   a. Hammond Lead Site -    On or about October 17, 2013, an employee, welder, who was welding on structural steel during the installation of a new ventilation system was exposed to an 8 hour time weighted average (TWA) of 108 micrograms of inorganic lead per cubic meter of air.  This level is 2.16 times the permissible exposure limit of 50 micrograms per cubic meter of air.  This exposure occurred over a 420 minute sampling period.  A zero exposure was assumed for the 60 minutes not sampled.   A zero exposure was assumed for the 60 minutes not sampled.  The employer did not provide zinc protoporphyrin testing.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339431710.