Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: HALLETT CINEMAS LLC DBA MAJESTIC CINEMAS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HALLETT CINEMAS LLC DBA MAJESTIC CINEMAS in 2140 E. CINEMA DRIVE, MERIDIAN, ID 83642 (NAICS 512131). OSHA activity number 339432544.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hallett Cinemas LLC DBA Majestic Cinemas for free Get an email when a new federal OSHA severe-injury report for Hallett Cinemas LLC DBA Majestic Cinemas is published. One employer, no account, unsubscribe in one click.
Site address
2140 E. CINEMA DRIVE
City
MERIDIAN
State
ID
ZIP
83642
Mailing
PO BOX 30, SUNNYSIDE, WA 98944
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
512131
Employees
34
Ownership type
Private (A)

10 citations on file for this inspection.

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 26, 2013
Abate by
Dec 31, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    (a)  Refreshment Counter: On or before October 4, 2013, and at times prior thereto, an employee cleaning a Mach 5 Popcorn Popper kettle was exposed to live electrical conductors (240 volts) due to the bottom cover being removed.    Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.332 B01

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  (a)  Refreshment counter, on or about July 8, 2013, and at times prior thereto, Mach 5 Popcorn Popper kettle was opened exposing live conductors (240Volts).  Employees, who were directed to clean the kettle above the live electrical conductors, were inadequately trained.  (b)  Refreshment counter, on or about July 8, 2013, and at times prior thereto, Mach 5 Popcorn Popper kettle was opened exposing live conductors (240Volts).  The Assistant Manager, who was directed to do service and maintenance on the popcorn popper while power was provided to the live electrical conductors, was not adequately trained.   Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.333 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 26, 2013
Abate by
Dec 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not deenergized before the employee worked on or was near to them:    (a)  Refreshment Counter, on or before October 4, 2013, and at times prior thereto, a Mach 5 Popcorn Popper kettle was opened exposing employees to live conductors (240 volts).  Employees re-energized and cleaned the kettle exposing them to live electrical conductors.    Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.333 A02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.333(a)(2): Where exposed live parts were not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices were not used to protect employees who could be exposed to the electrical hazards involved:   (a)  Refreshment counter, on or about July 8, 2013, and at times prior thereto, Mach 5 Popcorn Popper kettle was opened exposing live conductors (240Volts).  The Assistant Manager, who was directed to do service and maintenance on the popcorn popper.   Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.333 C02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.  (a)  Refreshment counter, on or about July 8, 2013, and at times prior thereto, Mach 5 Popcorn Popper kettle was opened exposing live conductors (240Volts).  The Assistant Manager, who was directed to do service and maintenance on the popcorn popper while power was provided to the live electrical conductors, was not adequately trained to use gloves and insulated tools.   Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.335 A02 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts:  (a)  Refreshment counter, on or about July 8, 2013, and at times prior thereto, Mach 5 Popcorn Popper kettle was opened exposing live conductors (240Volts).  The Assistant Manager, who was directed to do service and maintenance on the popcorn popper while power was provided to the live electrical conductors, was not adequately trained to use gloves and insulated tools.   Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.133 A01

Serious Gravity 1 1 instance 15 exposed
Issued
Nov 26, 2013
Abate by
Dec 31, 2013
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    (a)  Refreshment counter, on or about October 4, 2013, and at times prior thereto, Mach 5 Popcorn Popper, employees cleaning the kettle with Heat n' Kleen, did not wear eye protection that is recommended by the manufacturer.    Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2100

1910.1200 E01

Deleted Serious Gravity 1 1 instance 15 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a)  Refreshment counter, on or about October 4, 2013, and at times prior thereto, Mach 5 Popcorn Popper, employees cleaning the kettle with Gold Medal Products, Heat n' Kleen.  Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 G01

Deleted Serious Gravity 1 1 instance 15 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:  (a)  Refreshment counter, on or about October 4, 2013, and at times prior thereto, Mach 5 Popcorn Popper, employees cleaning the kettle with Gold Medal Products, Heat n' Kleen.  Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious 1 instance 15 exposed
Issued
Nov 26, 2013
Abate by
Dec 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1919.1200(h)(1):  Employees were not provided information and training as specified in 29 CFR 1910.1200(h)(2) and (3) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:    (a)  On or about October 4, 2013, and at times prior thereto, employees using hazardous chemicals including, but not limited to Gold Medal Products Co. Heat n' Kleen, had not received training on the chemical and were not aware of the locations of the Material Safety Data Sheet (MSDS) and the employer's written hazard communication program.    Note:  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339432544.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.