Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: ATLANTIC FURNITURE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ATLANTIC FURNITURE, INC. in 10 GREENFIELD RD, SOUTH DEERFIELD, MA 01373 (NAICS 337122). OSHA activity number 339433021.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlantic Furniture, INC. for free Get an email when a new federal OSHA severe-injury report for Atlantic Furniture, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10 GREENFIELD RD
City
SOUTH DEERFIELD
State
MA
ZIP
01373
Mailing
10 GREENFIELD RD, SOUTH DEERFIELD, MA 01373
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337122
Employees
14
Ownership type
Private (A)

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 29, 2014
Abate by
Feb 10, 2014
Penalty
Initial $2,200 · Current $1,100 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a crushing/struck by hazard from the steel/metal starage racks in the facility not being anchored to the floor:  (a) 10 Greenfield Rd South Deerfield, MA: On or about October 8, 2013 a steel storage rack used to store flat pack furniture pieces were not anchored to the floor, nor did the support vertical railings actually touch the floor for all supports. One feasible and acceptable method to correct this hazard would be to follow the installation instructions and the ANSI standard MH 16-1-2004 referencing the anchoring of storage racks.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2200

1910.23 A08

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 29, 2014
Abate by
Feb 6, 2014
Penalty
Initial $2,200 · Current $1,100 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk was not guarded or covered:  10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, there was an uncovered hole greater than 4 inches in diameter on the main walkway near the warehouse managers office, which is not in accordance with this subpart.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2200

1910.23 C01

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $2,200 · Current $1,100 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides:  (a) 10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, the upper landing area on the loading dock was greater than 4 FT elevation above the lower receiving area, and it was not guarded by a standard railing or its equivalent, which is not in accordance with this subpart.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2200

1910.37 A03

Serious Gravity 10 4 instances 14 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $3,080 · Current $1,100 Reduced
29 CFR 1910.37(a)(3): Exit routes were not free and unobstructed:    (a) 10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, numerous designated emergency exits in the warehouse portion of this facility were blocked with both product and/or waste materials, which is not in accordance with this subpart:
Recent events (2)
  • · I (S) $1100
  • · Z (S) $3080

1910.132 F01 V

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $2,200 · Current $1,100 Reduced
29 CFR 1910.132(f)(1)(v): Employees were not trained in the proper care, maintenance, useful life and disposal of the PPE supplied by the employer:    (a) 10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, a harness/lanyard involved in arresting an employee's fall on August 1, 2013 was still available for use contrary to the manufacturer's instructions that it be taken out of service/destroyed and the exposed employees had not been trained in the proper care, maintenance, useful life and disposal of the provided fall protection equipment in accordance with this subpart.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2200

1910.157 C01

Serious Gravity 5 4 instances 14 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $2,200 · Current $1,100 Reduced
29 CFR 1910.157(c)(1): The employer provided portable fire extinguishers were not readily accessible to employees:     (a)10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, 4 of the employer provided fire extinguishers in the warehouse at this facility were blocked by material, hidden from view by debris or otherwise not readily accessible to employees, which is not in accordance with this subpart.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2200

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $2,200 · Current $1,100 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years:    (a) 10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, an evaluation of the powered industrial truck operator's performance was not conducted since Sept 29, 2010, which is not in accordance with this subpart:
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2200

1910.178 Q07

Serious Gravity 5 2 instances 14 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined (at least daily) before being placed in service:    (a) 10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, industrial trucks that had not been inspected since July 16, 2013 were placed into service according to the records the company provided, which is not in accordance with this subpart:
Recent events (2)
  • · I (S) $0
  • · Z (S) $2200

1910.303 B02

Serious Gravity 5 2 instances 14 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $2,200 · Current $1,100 Reduced
29 CFR 1910.303(b)(2):Listed or labeled equipment was not installed and/or used in accordance with any instructions included in the listing or labeling:    (a)10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, 2 relocatable power taps used to power devices in the employee break area, were powered through extension cords, which is contrary to their labeling and listing that they receive power through a fixed receptacle, and not in complaince with this subpart:
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2200

1910.305 A02 I

Serious Gravity 5 3 instances 14 exposed
Issued
Jan 29, 2014
Abate by
Feb 10, 2014
Penalty
Initial $1,760 · Current $0 Reduced
29 CFR 1910.305(a)(2)(i):Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners. Note: Temporary electrical power and lighting installation(s) may only be used as specified by 1910.305(a)(2)(i)(A) through 1910.305(a)(2)(i)(C):     (a) 10 Greenfield Rd South Deerfield, MA: On or about October 8, 2013 3 orange extension cords were installed to provide electrical power to an employee breakroom at this facility, in lieu of permanant electrical wiring, which is not in accordance with this subpart.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1760

1910.303 G01

Serious Gravity 10 2 instances 14 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $3,080 · Current $1,100 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and/or maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:    (a)10 Greenfield Rd So Deerfield, MA: On or about October 8, 2013, the area directly in front of 2 electrical panels/switches providing service to the business at this address were blocked with debris and/or business product, which is not in accordance with this subpart:     Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
  • · I (S) $1100
  • · Z (S) $3080

View Atlantic Furniture, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339433021.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.