WASHINGTON, MO —
OSHA Inspection: CG POWER SYSTEMS USA INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CG POWER SYSTEMS USA INC. in #1 PAUWELS DRIVE, WASHINGTON, MO 63090 (NAICS 335311). OSHA activity number 339434425.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CG POWER SYSTEMS USA INC.
- Site address
- #1 PAUWELS DRIVE
- City
- WASHINGTON
- State
- MO
- ZIP
- 63090
- Mailing
- #1 PAUWELS DRIVE, WASHINGTON, MO 63090
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335311
- Employees
- 320
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.36 G02
- Issued
- Jan 24, 2014
- Penalty
- Initial $3,400 · Current $2,380 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): An exit access was not at least 28 inches (71.1 cm) wide at all points and the width of the exit and exit discharge was not at least equal to the width of the exit access: Center Bay: Employees were exposed to burns and smoke inhalation hazards where the nearest exit was blocked by a pallet of heavy metal materials which reduced the width of the exit discharge to 14 1/2 inches.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.176 B
- Issued
- Jan 24, 2014
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: Metal Shop: Damaged and twisted members of racking systems and bent upright members of the systems which were not secured to workplace floor created storage hazards to employees who used the storage systems.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
1910.178 P01
- Issued
- Jan 24, 2014
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Metal Shop: (a) A forklift with damaged tires was not removed from service until the condition was corrected. (b) Narrow Aisle Raymond powered industrial truck with protruding pinch points on the backrest was not removed from service until the condition was corrected. (c) A fork truck with damaged metal straps on the gas cylinder was not removed from service until the condition was corrected.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
1910.242 B
- Issued
- Jan 24, 2014
- Penalty
- Initial $2,168 · Current $1,518 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Metal Shop: Compressed air measured at 80 p.s.i. was used for cleaning purposes.
Recent events (2)
- — I (S) $1517.6
- — Z (S) $2168
1910.303 B07 IV
- Issued
- Jan 24, 2014
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: Finfold Welding area: Employees were exposed to electrical hazards where a broken receptacle of a quadruplet receptacle box was not corrected or removed from service.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
1910.305 G01 IV A
- Issued
- Jan 24, 2014
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Metal Shop: Employees were exposed to electrical hazards where a wall mounted duplex receptacle outlet box to which was connected a flexible cord was used to supply electrical power to a stationary water fountain, using the flexible cord as a substitute for fixed wiring.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
More inspections at CG Power Systems USA INC.
View CG Power Systems USA INC.'s full OSHA safety record →
More inspections in this industry (NAICS 335311)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339434425.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.