Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: AARON CRUZ

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AARON CRUZ in 2901 ENTERPRISE RD., APPLETON, WI 54911 (NAICS 238160). OSHA activity number 339435133.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aaron Cruz for free Get an email when a new federal OSHA severe-injury report for Aaron Cruz is published. One employer, no account, unsubscribe in one click.
Establishment
AARON CRUZ
Site address
2901 ENTERPRISE RD.
City
APPLETON
State
WI
ZIP
54911
Mailing
1119 MELISSA ST., MENASHA, WI 54952
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
Private (A)

5 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 22, 2014
Abate by
Feb 5, 2014
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:     a)  On September 26, 2013, four employees working a commercial building at 2901 E. Enterprise Avenue, Appleton, WI 54911, were not protected from falling approximately 12 feet from the eave of the roof by the use of a fall protection system or equipment.    ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • · I (S) $1960
  • · Z (S) $2800

1926.502 D15

Serious Gravity 10 4 instances 4 exposed
Issued
Jan 22, 2014
Abate by
Feb 5, 2014
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:    a) A rope that was part of a personal fall system was directly tied to the anchor with no connector attached.    ABATEMENT DOCUMENTATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
  • · I (S) $1960
  • · Z (S) $2800

1926.502 D15 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 22, 2014
Abate by
Jan 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, and not installed under the supervision of a qualified person:  a)  Two employees were sharing one anchor point on separate lifelines.  The anchor was designed for only one lifeline.  b)  A rope that was part of a personal fall system was directly tied to the anchor with no connector attached.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.502 D16 II

Serious Gravity 10 4 instances 4 exposed
Issued
Jan 22, 2014
Abate by
Feb 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(ii): 29 CFR 1926.502 (d)(16)(ii): Personal fall arrest systems, when stopping a fall, did not limit the maximum arresting force on an employee to 1800 pounds (8kn) when used with a body harness:   a)  The personal arrest system that the employees were using did not have a shock absorber that would stop a fall with a maximum arresting force on an employee to 1800 pounds.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.502 D17

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 22, 2014
Abate by
Jan 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:  a) An employee was wearing the attachment point of the harness lower than the center of his back.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Aaron Cruz's full OSHA safety record →