FREMONT, NE ·
OSHA Inspection: CON AGRA MILLS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CON AGRA MILLS in 125 SOUTH BROAD STREET, FREMONT, NE 68025 (NAICS 311211). OSHA activity number 339435364.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CON AGRA MILLS
- Site address
- 125 SOUTH BROAD STREET
- City
- FREMONT
- State
- NE
- ZIP
- 68025
- Mailing
- 125 SOUTH BROAD STREET, FREMONT, NE 68025
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311211
- Employees
- 16
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 19, 2013
- Abate by
- May 12, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: The employer failed to protect employees from potential caught between and amputation hazards associated with unguarded rotating parts. This was most recently evident during the inspection of the facility located at 125 South Broad St. Fremont, NE 68025, where the employer has flour mill employees operating and cleaning around the BK4 sifter located on the 5th floor without guarding the point of operation on the sifter created by the swiftly moving counter weights.
Recent events (3)
- · F (S) $7000
- · C (S) $7000
- · Z (S) $7000
1910.219 D01
- Issued
- Dec 19, 2013
- Abate by
- May 12, 2015
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): The employer failed to protect employees from potential caught between and amputation hazards associated with unguarded belts and pulleys on milling equipment. This was most recently evident during the inspection of the facility located at 125 South Broad St. Fremont, NE 68025, where the employer has flour mill employees operating and cleaning around the BK4 sifter located on the 5th floor without guarding the belt and pulley assembly mounted on the top of the sifter.
Recent events (3)
- · F (S) $2500
- · C (S) $5000
- · Z (S) $5000
1910.219 E01 I
- Issued
- Dec 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: The employer failed to protect employees from potential caught between and amputation hazards associated with unguarded belts and pulleys on milling equipment. This was most recently evident during the inspection of the facility located at 125 South Broad St. Fremont, NE 68025, where the employer has flour mill employees operating and cleaning around the BK4 sifter located on the 5th floor without guarding the belt and pulley assembly mounted on the top of the sifter.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.272 J03
- Issued
- Dec 19, 2013
- Abate by
- Jan 8, 2014
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.272(j)(3): Compressed air was used to blow dust from ledges, walls, and other areas in grain handling facilities when machinery presenting an ignition source was not shut down, and/or when all other known potential ignition sources in the area had not been removed or controlled: The employer failed to protect employees from potential explosion hazards associated with using compressed air to clean grain handling facilities without eliminating all potential ignition sources. This was most recently evident during the inspection of the facility located at 125 South Broad St. Fremont, NE 68025, where the employer has flour mill employees using compressed air hoses and nozzles rated at 30psi for cleaning around the third, fourth and fifth floors of the flour mill while all equipment is still operating and potential ignition sources exist. Instances include but are not limited to: i. Belt and pulley assemblies on top of the sifters where potential bearing failures could create enough heat to ignite the highly flammable flour dust as it is blown into the air in its smallest particulate form. ii. Chain and sprocket assemblies along all of the horizontal and vertical auger systems on the third and fourth floors where a bearing failure could create enough heat to ignite the highly flammable flour dust as it is blown into the air in its smallest particulate form. iii. Missing light switch cover on the overhead light switch located on the fifth floor.
Recent events (3)
- · F (S) $0
- · C (S) $7000
- · Z (S) $7000
1910.305 C04
- Issued
- Dec 19, 2013
- Abate by
- May 12, 2015
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.305(c)(4): Faceplates for flush-mounted snap switches. Snap switches mounted in boxes shall have faceplates installed so as to completely cover the opening and seat against the finished surface. The employer failed to protect employees from potential electrical hazards associated with missing faceplates on light switches. This was most recently evident during the inspection of the facility located at 125 South Broad St. Fremont, NE 68025, where the employer has flour mill employees working throughout the facility and the light switch for the fifth floor ceiling lights is located directly next to the door is missing the cover leaving the 110v electrical lines exposed.
Recent events (3)
- · F (O) $3500
- · C (S) $7000
- · Z (S) $7000
More inspections in this industry (NAICS 311211)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339435364.