Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION in 6930 SAND LAKE ROAD, ANCHORAGE, AK 99502 (NAICS 561210). OSHA activity number 339436313.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Oceanic and Atmospheric Administration for free Get an email when a new federal OSHA severe-injury report for National Oceanic and Atmospheric Administration is published. One employer, no account, unsubscribe in one click.
Site address
6930 SAND LAKE ROAD
City
ANCHORAGE
State
AK
ZIP
99502
Mailing
222 W 7TH AVE #23 ROOM 517, ANCHORAGE, AK 99513
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
3
Ownership type
Federal government (D)

8 citations on file for this inspection.

1910.37 A04

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 25, 2013
Abate by
Nov 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times.  Wood Shop Area:  On or about 22 October 2013 and times prior thereto, emergency lighting in the wood shop was inoperable.  This exposed employees to smoke inhalation and/or fire hazards from delays in exiting the building.
Recent events (1)
  • · Z (S) $0

1910.215 B09

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 25, 2013
Abate by
Nov 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.  Wood Shop Area:  On or about 22 October 2013 and times prior thereto, both tongue guards on the  JET 8" Bench grinder, serial number 2090788, were not installed properly and distance of wheel to guards measured approximately 3/8 inch.  This condition exposed employees to a struck by hazard.
Recent events (1)
  • · Z (S) $0

1910.242 B

Serious Gravity 5 3 instances 3 exposed
Issued
Oct 25, 2013
Abate by
Nov 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  Wood Shop Area:  On or about 22 October 2013 and times prior thereto, air nozzles provided to employees did not reduce air pressure to 30 P.S.I.  Shop air was set at approximately 100 P.S.I.   This exposed employees to air embolism/laceration hazards if they contacted the discharge to their skin.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 3 exposed
Issued
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  Wood Shop and Garage Area:  On or about 22 October 2013 and times prior thereto, two locally fabricated, 120 volt, 4-plug junction box was wired to an extension cord.  This exposed employees to a 120 volt electrical shock hazard.
Recent events (1)
  • · Z (S) $0

1910.303 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 25, 2013
Abate by
Nov 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.  Outside shop, west side of building:  On or about 22 October 2013 and times prior thereto, 120 volt, electrical panel LP-3 did not have a label identifying the circuit.  This condition exposed employees to an electrical shock hazard.
Recent events (1)
  • · Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 25, 2013
Abate by
Nov 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  Outside building, west side:  On or about 22 October 2013 and times prior thereto, 120 volt circuit breaker panel LP-3 was obstructed. This condition exposed employees to electrical shock and burn hazards.
Recent events (1)
  • · Z (S) $0

1910.305 A02 IX

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination shall be protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded.  Garage area:  On or about 22 October 2013 and times prior thereto, a 120 volt, BB-2870 portable light was missing its guard. This condition exposed employees to an electrical shock and burn hazard.
Recent events (1)
  • · Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 25, 2013
Abate by
Nov 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  Garage area:  On or about 22 October 2013 and times prior thereto, a 120 volt, Porter-Cable belt sander, Model 360, serial number 099929 had a frayed cord exposing wires.  This condition exposed employees to an electrical shock and burn hazard.
Recent events (1)
  • · Z (S) $0

View National Oceanic and Atmospheric Administration's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339436313.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.