LINCOLN, NE —
OSHA Inspection: NORLAND INTERNATIONAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORLAND INTERNATIONAL, INC. in 2001 SW 6TH ST., LINCOLN, NE 68522 (NAICS 333922). OSHA activity number 339437261.
Where did this inspection happen?
- Establishment
- NORLAND INTERNATIONAL, INC.
- Site address
- 2001 SW 6TH ST.
- City
- LINCOLN
- State
- NE
- ZIP
- 68522
- Mailing
- 2001 SW 6TH ST., LINCOLN, NE 68522
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333922
- Employees
- 48
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.101 B
- Issued
- Penalty
- Initial $1785.00 · Current $1250.00 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6: 2001 SW 6th Street, Lincoln, NE 68522 (Wash Bay): The employer did not ensure that the storage of a carbon dioxide gas cylinder was adequate. The cylinder was located by an employee pathway and the cylinder was secured by a chain around the nozzle and did not have the valve cap secured on the cylinder while it was in storage.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $2083.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the items of this section: 2001 SW 6th Street, Lincoln, NE 68522 (Site-Wide): The employer did not ensure that the lockout procedures used by employees to service equipment were adequately specific. The procedures had generic steps for locking out equipment, but did not have specific procedures to lock out equipment, including, but not limited to, the Blow Molder. Abatement certification and abatement documentation is required for this violation. The abatement certification sheet is enclosed.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.212 A03 II
- Issued
- Penalty
- Initial $2529.00 · Current $1770.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): 2001 SW 6th Street, Lincoln, NE 68522 (Shear Area): The employer did not ensure that adequate machine guarding was provided on equipment including, but not limited to, 1) Cincinnati Shear at the point of operation.
Recent events (2)
- — I (S) $1770.3
- — Z (S) $2529
1910.219 D01
- Issued
- Penalty
- Initial $2023.00 · Current $1416.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): 2001 SW 6th Street, Lincoln, NE 68522 (Unscrambler Area): The employer did not ensure that a pulley was adequately guarded on the Unscrambler.
Recent events (2)
- — I (S) $1416.1
- — Z (S) $2023
1910.219 E03 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): 2001 SW 6th Street, Lincoln, NE 68522 (Unscrambler Area): The employer did not ensure that the inclined belt was adequately guarded on the Unscrambler.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 333922)
MITCHELL, IN—2026-07-09 00:00:00
C AND M CONVEYOR INC
BRIGHTON, MI—2026-06-04 00:00:00
ALLOR MANUFACTURING
GADSDEN, AL—2026-05-18 00:00:00
WEBB-STILES OF ALABAMA, INC.
NORTON SHORES, MI—2026-04-27 00:00:00
DYNAMIC CONVEYOR CORPORATION
SAINT PAUL, MN—2026-04-22 00:00:00
111112 - TECH LOGIC CORPORATION
More inspections in NE
CRETE, NE—2026-07-15 00:00:00
SMITHFIELD FOODS
OMAHA, NE—2026-07-14 00:00:00
LACO ENTERPRISES, LLC
OMAHA, NE—2026-07-10 00:00:00
WINGSTOP
LINCOLN, NE—2026-07-01 00:00:00
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30 00:00:00
PATRIOT PLUMBING, HEATING & AC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339437261.