LA GRANGE, IL —
OSHA Inspection: MARK C. TEETSOV
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARK C. TEETSOV in 220 S WAIOLA AVE., LA GRANGE, IL 60525 (NAICS 238390). OSHA activity number 339438541.
Where did this inspection happen?
- Establishment
- MARK C. TEETSOV
- Site address
- 220 S WAIOLA AVE.
- City
- LA GRANGE
- State
- IL
- ZIP
- 60525
- Mailing
- 544 CIRCLE AVENUE #2, FOREST PARK, IL 60130
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 3
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.451 A06
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory Appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section. a. On or about October 23, 2013 - at the above addressed jobsite, an employee was performing finish trim installation from a tubular welded frame scaffold in conjunction with a ladder jack scaffold, approximately sixteen (16) feet above the ground, that was not designed by a qualified person, thereby exposing the employee to a fall hazard.
Recent events (2)
- — I (S) $900
- — Z (S) $1600
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable: a. On or about October 23, 2013 - at the above addressed jobsite, an employee using a tubular welded frame scaffold in conjunction with a ladder jack scaffold was not trained to recognize the hazards associated with the use of such scaffolds, thereby exposing the employee to the hazards associated with falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: On or about October 23, 2013 - at the above addressed jobsite, an employee was performing finish trim installation from a tubular welded frame scaffold which did not have the working platforms fully planked, thereby exposing the employee to a fall of approximately sixteen (16) feet.
Recent events (2)
- — I (S) $1600
- — Z (S) $2800
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. a. On or about October 23, 2013 - at the above addressed jobsite, an employee performing finish trim installation from a tubular welded frame scaffold, approximately sixteen (16) feet above the ground, was exposed to injuries from falls due to the lack of guardrails.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a. On or about October 23, 2013 - at the above addressed jobsite, an employee was performing finish trim installation from a tubular welded frame scaffold approximately sixteen (16) feet above the ground, that was not provided with base plates or mud sills, thereby exposing the employee to falls.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1926.452 C03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(c)(3): Frames and panels shall be joined together vertically by coupling or stacking pins or equivalent means. On or about October 23, 2013 - at the above addressed jobsite, an employee was performing finish trim installation from a tubular welded frame scaffold approximately sixteen (16) feet above the ground, which had frames that were not joined together vertically by the use of stacking pins. The employee was thereby exposed to the hazards associated with scaffolding collapse.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B05 II
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a. On or about October 23, 2013 - at the above addressed jobsite, an employee was performing finish trim installation from a tubular welded frame scaffold in conjunction with a ladder jack scaffold that had a platform extending greater than eighteen (>18") inches past its supports, thereby exposing the employee to a fall of approximately sixteen (16) feet.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. a. On or about October 23, 2013 - at the above addressed jobsite, an employee used a six (6) foot step ladder as means of support to a ladder jack scaffold plank. This type of a ladder is not designed for such purpose, thereby exposing the employee to the hazards associated with falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238390)
WILMINGTON, NC—2026-07-09
161520 - LH ROOFING AND REMODELING LLC
ADDED FOR LEGACY MIGRATION, UK—2026-07-08
317744725 - WESTMARK CONSTRUCTION INC
BROOKLYN, NY—2026-07-08
SKYLINE RESTORATION INC.
LEBANON, PA—2026-07-01
STRUCTURAL RESTORATION SERVICES, INC
LEBANON, PA—2026-07-01
STRUCTURAL RESTORATION SERVICES, INC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339438541.