Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ANALIA STUCCO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANALIA STUCCO, INC. in 4738 PLANTATION OAKS BLVD. LOT 153, ORANGE PARK, FL 32065 (NAICS 238140). OSHA activity number 339439630.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Analia Stucco, INC. for free Get an email when a new federal OSHA severe-injury report for Analia Stucco, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ANALIA STUCCO, INC.
Site address
4738 PLANTATION OAKS BLVD. LOT 153
City
ORANGE PARK
State
FL
ZIP
32065
Mailing
5823 DIEGO STREET #8, ORLANDO, FL 32807
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 22, 2013
Abate by
Dec 3, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a. On or about October 22, 2013, the employee mixing cement was not wearing safety glasses, exposing himself to possible eye injuries.
Recent events (1)
  • · Z (S) $1200

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 22, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights:  a. On or about October 22, 2013, an employee applying stucco from the first level of the scaffold system that was not fully planked and the platform only had two planks with gaps, exposing the employee to a 6 feet fall hazard.  Abatement Certification and Documentation are not required
Recent events (1)
  • · Z (S) $2000

1926.451 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 22, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  a. On or about October 22, 2013, front and left side of the home, the two buck high scaffold systems were erected in the sand did not have mudsills or base plates, exposing employees to crushing hazards.  Abatement Certification and Documentation are not required
Recent events (1)
  • · Z (S) $2800

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 22, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used:  a. On or about October 22, 2013, the employee accessed the first level of the scaffold sytem by climbing the rungs.  The scaffold system was not equipped with a ladder, exposing the employee to a 6 feet fall hazard.  Abatement Certification and Documentation are not required.
Recent events (1)
  • · Z (S) $2000

1926.451 F07

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 22, 2013
Abate by
Dec 19, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:  a. On or about October 22, 2013, employees applying stucco on the front of the home were working on a scaffold system that was not erected under the supervision of a competent person.