Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MISTRAS GROUP, INC. in 600 KAISER DRIVE, HEATH, OH 43056 (NAICS 331319). OSHA activity number 339440596.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mistras Group, INC. for free Get an email when a new federal OSHA severe-injury report for Mistras Group, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MISTRAS GROUP, INC.
Site address
600 KAISER DRIVE
City
HEATH
State
OH
ZIP
43056
Mailing
600 KAISER DRIVE, HEATH, OH 43056
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331319
Employees
40
Ownership type
Private (A)

10 citations on file for this inspection.

1910.179 F06 III

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 14, 2014
Abate by
Mar 7, 2014
Penalty
Initial $7,000 · Current $4,550 Reduced
29 CFR 1910.179(f)(6)(iii): On all floor, remote and pulpit-operated crane bridge drives, a brake of noncoasting mechanical drive shall be provided.  a. At the site located in Heath, Ohio the employer had a Northern 10 ton (#27) overhead crane that was not equipped with functioning brakes.  On or about October 18, 2013 an employee was struck by a stack of aluminum that was being loaded onto a flatbed trailer with crane #27.
Recent events (2)
  • · I (S) $4550
  • · Z (S) $7000

1910.179 H01 III

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 14, 2014
Abate by
Mar 12, 2014
Penalty
Initial $5,500 · Current $3,575 Reduced
29 CFR 1910.179(h)(1)(iii): The sheaves in the bottom block shall be equipped with close-fitting guards that will prevent ropes from becoming fouled when the block is lying on the ground with ropes loose.  a. At the site located in Heath, Ohio the employer had a Northern 10 ton (#27) overhead crane that was not equipped with a guard on the bottom block that prevented the ropes from coming out of the sheaves or protected the ingoing nip point between the sheaves and the running rope.
Recent events (2)
  • · I (S) $3575
  • · Z (S) $5500

1910.179 J02

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 14, 2014
Abate by
Mar 7, 2014
Penalty
Initial $5,500 · Current $3,575 Reduced
29 CFR 1910.179(j)(2): Frequent inspection. The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:  a. At the site located in Heath, Ohio the employer had employees that operated a 10 ton Northern Crane (# 27) that were not performing the frequent inspections as required by the standard.  The crane had several deficiencies that should have been discovered during frequent inspections such as but not limited to non-functioning brakes, missing safety latch, and a handle welded onto the hook.
Recent events (2)
  • · I (S) $3575
  • · Z (S) $5500

1910.179 N03 XI

Serious Gravity 1 1 instance 4 exposed
Issued
Feb 14, 2014
Abate by
Mar 12, 2014
Penalty
Initial $3,300 · Current $2,145 Reduced
29 CFR 1910.179(n)(3)(xi): When starting the bridge and when the load or hook approaches near or over personnel, the warning signal shall be sounded.  a. At the site located in Heath, Ohio the employer had a Northern 10 ton (#27) overhead crane that did not have a functioning horn.
Recent events (2)
  • · I (S) $2145
  • · Z (S) $3300

1910.184 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Feb 14, 2014
Abate by
Mar 7, 2014
Penalty
Initial $5,500 · Current $3,575 Reduced
29 CFR 1910.184(c)(1): Slings that are damaged or defective shall not be used.  a. At the site located in Heath, Ohio the employer had a synthetic fiber web sling that was still in service on the 10 ton Northern Crane (#27) that had damaged / cut fibers and the sling was not removed from service.
Recent events (2)
  • · I (S) $3575
  • · Z (S) $5500

1910.184 D

Serious Gravity 5 2 instances 4 exposed
Issued
Feb 14, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.184(d): Inspections. Each day before being used, the sling and all fastenings and attachments shall be inspected for damage or defects by a competent person designated by the employer. Additional inspections shall be performed during sling use, where service conditions warrant. Damaged or defective slings shall be immediately removed from service.  a. At the worksite located in Heath, Ohio the employer had employees that were using a 10 ton overhead crane with slings that were not being inspected by a competant person that had the knowledge to remove the slings from service based on the issues on the slings, such as but not limited to snags, tears, cuts, and broken or worn stitches.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.184 I09 II

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 14, 2014
Abate by
Mar 7, 2014
Penalty
Initial $5,500 · Current $3,575 Reduced
1910.184(i)(9)(iii): Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present: Snags, punctures, tears or cuts  a. At the site located in Heath, Ohio the employer had kept damaged synthetic web slings available for use in the shipping and receiving area that had tears, cuts, and broken and worn stitches.
Recent events (2)
  • · I (S) $3575
  • · Z (S) $5500

1910.184 I09 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 14, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
1910.184(i)(9)(iv): Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present:  Broken or worn stitches; or  a. At the site located in Heath, Ohio the employer had kept damaged synthetic web slings available for use in the shipping and receiving area that had tears, cuts, and broken and worn stitches.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 D02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 14, 2014
Penalty
Initial $5,500 · Current $3,575 Reduced
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.  a. At the site located in Heath, Ohio the employer had a panel board that was not dead front because the cover for the enclosure was damaged and left open thereby exposing employees to electric shock.
Recent events (2)
  • · I (S) $3575
  • · Z (S) $5500

1910.305 G01 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 14, 2014
Abate by
Mar 22, 2014
Penalty
Initial $5,500 · Current $3,575 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:  As a substitute for the fixed wiring of a structure;   a.  At the work site located in Heath, Ohio the employer had used multiple extension cords to power all of the lights in the radiography bay rather than installing permanently wired equipment.