Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: ROMA TOOL & PLASTICS, DIV. OF INFOPAC IMAGING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROMA TOOL & PLASTICS, DIV. OF INFOPAC IMAGING, INC. in 107 W. PROSPECT AVE., ALMENA, WI 54805 (NAICS 326199). OSHA activity number 339441362.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roma Tool & Plastics, DIV. of Infopac Imaging, INC. — free Get an email when a new federal OSHA severe-injury report for Roma Tool & Plastics, DIV. of Infopac Imaging, INC. is published. One employer, no account, unsubscribe in one click.
Site address
107 W. PROSPECT AVE.
City
ALMENA
State
WI
ZIP
54805
Mailing
107 W. PROSPECT AVE., ALMENA, WI 54805
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 13, 2013
Abate by
Dec 20, 2013
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    a) Throughout the facility; The energy control procedures did not identify all of the potentially hazardous energy sources and how to isolate and secure the energy such as but not limited to; identifying hydraulic energy and application of controls.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $1700

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 13, 2013
Abate by
Dec 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    a) Throughout the facility; The employees are removing jams on presses without affixing lockout or tagout devices to the energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 D01 II

Other-than-serious 1 instance 4 exposed
Issued
Nov 13, 2013
Abate by
Dec 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1)(ii): Stairway(s) less than 44 inches wide having one side open, did not have at least one stair railing on the open side:    a) At the stairs going up to the offices; The stairs going up to the office had an open side with one handrail on the open side rather than a stair railing consisting of a top rail and an intermediate rail.