TULSA, OK ·
OSHA Inspection: CONTINENTAL INDUSTRIES, A DIVISION OF BURNDY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONTINENTAL INDUSTRIES, A DIVISION OF BURNDY LLC in 1140 N. 129TH EAST AVE., TULSA, OK 74116 (NAICS 332812). OSHA activity number 339441966.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTINENTAL INDUSTRIES, A DIVISION OF BURNDY LLC
- Site address
- 1140 N. 129TH EAST AVE.
- City
- TULSA
- State
- OK
- ZIP
- 74116
- Mailing
- 1140 N. 129TH EAST AVE., TULSA, OK 74116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 140
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 16, 2013
- Abate by
- Mar 21, 2014
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about October 23, 2013, and at times prior thereto, in the Automatic Line areas at the Broken Arrow facility employees were allowed to operate automated screw machines that were found not having interlock device provided on the doors. Employees were exposed to possible amputation hazards.
Recent events (2)
- · I (S) $2040
- · Z (S) $3400
1910.304 B02
- Issued
- Dec 16, 2013
- Abate by
- Jan 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: On or about October 22, 2013, or at times prior thereto, in the shop break room at the Tulsa facility was observed having electrical equipment were plugged into the same outlet device which had a current rating less than the load being served. This exposed employees to fire hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332812)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339441966.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.