On , OSHA opened a complaint safety inspection of FRICK'S QUALITY MEATS in 360 M. E. FRICK DRIVE, WASHINGTON, MO 63090 (NAICS 311612). OSHA activity number 339443012.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRICK'S QUALITY MEATS
- Site address
- 360 M. E. FRICK DRIVE
- City
- WASHINGTON
- State
- MO
- ZIP
- 63090
- Mailing
- 360 M. E. FRICK DRIVE, WASHINGTON, MO 63090
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 140
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.119 E01
- Issued
- Nov 4, 2013
- Abate by
- Feb 5, 2014
- Penalty
- Initial $3,713 · Current $2,599 Reduced
General-duty citation text
29 CFR 1910.119(e)(1): The employer shall perform an initial process hazard analysis (hazard evaluation) on processes covered by this standard. The process hazard analysis shall be appropriate to the complexity of the process and shall identify, evaluate, and control the hazards involved in the process. At the time of the inspection, the employer had not a hazard evaluation for the ammonia refrigeration system that contained apprximately 14,414 pounds of ammonia. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- · I (S) $2599.1
- · Z (S) $3713
1910.219 D01
- Issued
- Nov 4, 2013
- Abate by
- Nov 22, 2013
- Penalty
- Initial $2,970 · Current $2,079 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): At the time of the inspection, the belts and pulleys of the #4 reciprocating compressor were not guarded as required by this section. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- · I (S) $2079
- · Z (S) $2970
1910.307 C
- Issued
- Nov 4, 2013
- Abate by
- Mar 21, 2014
- Penalty
- Initial $3,713 · Current $2,599 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: At the time of the inspection, the electrical wiring in the engine room was not approved for Division 1 class 2 hazards resulting from the potential exposure to explosive levels of ammonia. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- · I (S) $2599.1
- · Z (S) $3713
1910.38 C03
- Issued
- Nov 4, 2013
- Abate by
- Dec 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(c)(3): Procedures to be followed by employees who remain to operate critical plant operations before they evacuate; At the time of the inspection, the employers emergency action plan did not address the steps to be taken by the refrigeration system operator to respond to small releases of ammonia.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Frick'S Quality Meats
View Frick'S Quality Meats's full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339443012.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.