DENVER, CO ·
OSHA Inspection: PURPLE MOUNTAIN BUILDERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PURPLE MOUNTAIN BUILDERS, INC. in 2002 WEST 76TH AVE. BUILDING 26, DENVER, CO 80221 (NAICS 238170). OSHA activity number 339444614.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PURPLE MOUNTAIN BUILDERS, INC.
- Site address
- 2002 WEST 76TH AVE. BUILDING 26
- City
- DENVER
- State
- CO
- ZIP
- 80221
- Mailing
- 786 KISKER COURT, COLORADO SPRINGS, CO 80911
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Jan 17, 2014
- Penalty
- Initial $1,156 · Current $578 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Purple Mountain Builders, Inc. at 2002 West 76th Ave. Building # 26, Denver, CO 80221: On or before October 23, 2013, the employer did not ensure that siding subcontractor employees wore safety glasses when using or working in the vicinity of pneumatic nail guns. Condition exposed siding subcontractor employees to the hazard of projectiles to the eyes.
Recent events (2)
- · I (S) $578
- · Z (S) $1156
1926.451 G01 VII
- Issued
- Jan 17, 2014
- Abate by
- Feb 13, 2014
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet above lower level, was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) Purple Mountain Builders, Inc. at 2002 West 76th Ave. Building # 26, Denver, CO 80221: On or before October 23, 2013, the employer did not ensure that siding subcontractor employees were protected from falling when using the pump jack scaffold in the following instances: 1) The guardrail system did not include midrails; 2) The guardrail system did not include endrails; 3) The 2 x 4 top rails would not support a 200 pound load as specified in 29 CFR 1926.451(g)(4) because: a) the guardrails were supported only by the vertical pump jack stands that were placed up to 15 feet apart, and the distance between vertical supports exceeded 8 feet as specified in 1926 Subpart M Appendix B; b) the top rails were not properly secured to the uprights; These employees were not wearing personal fall arrest systems. Condition exposed these employees to fall hazards of up to 18 feet.
Recent events (2)
- · I (S) $850
- · Z (S) $1700
1926.404 B01 II
- Issued
- Jan 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters (GFCIs) for personal protection: a) Lake Construction LLC at 2002 West 76th Ave. Building # 26, Denver, CO 80221: On or before October 23, 2012, the employer did not ensure that a GFCI was in use when employees cut siding using a 120 volt Dewalt circular saw model DWS535, serial number 153739, that was not double insulated. Condition exposed employees to an electrical shock hazard.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238170)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339444614.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.