Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: BANYAI CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BANYAI CONSTRUCTION in 2163 DUNMARE LN NW, WASHINGTON, DC 20017 (NAICS 238160). OSHA activity number 339448698.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Banyai Construction for free Get an email when a new federal OSHA severe-injury report for Banyai Construction is published. One employer, no account, unsubscribe in one click.
Establishment
BANYAI CONSTRUCTION
Site address
2163 DUNMARE LN NW
City
WASHINGTON
State
DC
ZIP
20017
Mailing
21108 WALKLEY HILL PLACE, ASHBURN, VA 20148
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
Private (A)

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Dec 3, 2013
Abate by
Dec 20, 2013
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) On October 21, 2013 and at times prior thereto; roof area; employees were observed working on a multi pitch roof (10:12 and 2:12) without a personal fall arrest system in place to prevent them from falling 30-40 feet to ground level.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $1540
  • · Z (S) $3080

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 3, 2013
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    On October 21, 2013 and at times prior thereto; front area; the ladder used to access the platform area was extended eighteen inches above the working platform.
Recent events (2)
  • · I (S) $1540
  • · Z (S) $3080

1926.1053 B04

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 3, 2013
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:   On October 21, 2013 and at times prior thereto; roof area; employees were using an extension ladder section in place of a roof ladder.
Recent events (2)
  • · I (S) $1540
  • · Z (S) $3080

View Banyai Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339448698.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.