WASHINGTON, DC —
OSHA Inspection: STAY DRY EXTERIORS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STAY DRY EXTERIORS INC in 1602 FOXHALL RD, WASHINGTON, DC 20015 (NAICS 238160). OSHA activity number 339448904.
Where did this inspection happen?
- Establishment
- STAY DRY EXTERIORS INC
- Site address
- 1602 FOXHALL RD
- City
- WASHINGTON
- State
- DC
- ZIP
- 20015
- Mailing
- 19204 STALEY BRIDGE RD, GERMANTOWN, MD 20876
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 G01
- Issued
- Penalty
- Initial $1530.00 · Current $1071.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On October 22, 2013 and at times prior thereto; front of building; employees were working on a scaffold system without adequate means of fall protection in place to protect them from falling to ground level.
Recent events (2)
- — I (S) $1071
- — Z (S) $1530
1926.501 B13
- Issued
- Penalty
- Initial $2520.00 · Current $1264.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On October 22, 2013 and at times prior thereto; roof area; employees were observed working on a multi pitch roof (12:12 and 16:12) without a personal fall arrest system in place to prevent them from falling 20-30 feet to ground level.
Recent events (2)
- — I (S) $1264
- — Z (S) $2520
1926.1053 B01
- Issued
- Penalty
- Initial $1224.00 · Current $865.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing a) On October 22, 2013 and at times prior thereto; front area; the ladder used to access the platform area was extended eighteen inches above the working platform.
Recent events (2)
- — I (S) $865
- — Z (S) $1224
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339448904.