CANAAN, CT —
OSHA Inspection: INTERIOR DRYWALL SYSTEM CONSTRUCTION, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of INTERIOR DRYWALL SYSTEM CONSTRUCTION, LLC in SOUTH CANAAN ROAD, CANAAN, CT 06018 (NAICS 238130). OSHA activity number 339450454.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERIOR DRYWALL SYSTEM CONSTRUCTION, LLC
- Site address
- SOUTH CANAAN ROAD
- City
- CANAAN
- State
- CT
- ZIP
- 06018
- Mailing
- 18 CALLAHAN LANE, EAST HARTFORD, CT 06118
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Nov 29, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 10/25/2013 at the Mountainside Treatment Center Expansion Project, an employee was working from a tubular welded frame scaffold and the working level was not fully planked.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.502 B01
- Issued
- Nov 29, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: On or about 10/25/2013 at the Mountainside Treatment Center Expansion Project, employees were exposed to fall hazards while working from the 2nd floor and the top rail of the cable guardrail system in use as fall protection was lower than the 42 inches plus or minus 3 inches requirements.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- Nov 29, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about 10/25/2013 at the Mountainside Treatment Center Expansion Project, employees were using an extension ladder to access the second floor and the ladder extended only 17 inches past the landing.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections at Interior Drywall System Construction, LLC
View Interior Drywall System Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339450454.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.