OSHA Inspection: ALASKA NATIVE TRIBAL HEALTH CONSORTIUM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALASKA NATIVE TRIBAL HEALTH CONSORTIUM in 4315 DIPLOMACY DRIVE, ANCHORAGE, AK 99508 (NAICS 622110). OSHA activity number 339454456.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alaska Native Tribal Health Consortium — free Get an email when a new federal OSHA severe-injury report for Alaska Native Tribal Health Consortium is published. One employer, no account, unsubscribe in one click.
Site address
4315 DIPLOMACY DRIVE
City
ANCHORAGE
State
AK
ZIP
99508
Mailing
4000 AMBASSADOR DRIVE, ANCHORAGE, AK 99508
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
1200
Ownership type
A

6 citations on file for this inspection.

1910.132 A

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 15, 2013
Abate by
Dec 12, 2013
Penalty
Initial $2,550 · Current $1,913 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered.    Maintenance Garage:  On or about 29 October 2013 and times prior thereto, employees were operating gas powered chainsaws without chaps This condition exposed employees to caught in hazard.
Recent events (2)
  • — I (S) $1912.5
  • — Z (S) $2550

1910.132 D01

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 15, 2013
Abate by
Dec 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE).  Maintenance Garage:  On or about 29 October 2013 and times prior thereto, employees were operating gas powered chainsaws without a hazard assessment identifying what PPE was required for the task.  This condition exposed employees to caught in hazard by operating chain saws without chaps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.176 A

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 15, 2013
Penalty
Initial $2,168 · Current $1,626 Reduced
29 CFR 1910.176(a): Aisle(s) and passageway(s) were not kept clear and in good repair with no obstruction across or in aisles that could create a hazard.    Tank Storage Room Area:  On or about 29 October 2013 and times prior thereto, the aisle way adjacent to upper deck area measured approximately 16 inches.  This condition exposed employees to delays in existing the building creating tripping, smoke inhalation and fire hazards.
Recent events (2)
  • — I (S) $1626
  • — Z (S) $2168

1910.254 D09 III

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 15, 2013
Penalty
Initial $2,168 · Current $1,626 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced.      Welding Shop area:  On or about 29 October 2013 and times and prior thereto, the Hobart welder, Model TR-300, serial number 2RT-17010, had cut insulation approximately 6 feet from the stinger.  This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
  • — I (S) $1626
  • — Z (S) $2168

1910.303 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 15, 2013
Penalty
Initial $2,168 · Current $1,626 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.    Switch Gear Room:  on or about 29 October 2013 and times prior thereto the electrical panel beside panel BX2A was not labeled to identify what circuit was controlled by the panel.  This condition exposed employees to a 120 volt electrical shock and burn hazard.
Recent events (2)
  • — I (S) $1626
  • — Z (S) $2168

1910.334 A02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 15, 2013
Penalty
Initial $15,000 · Current $11,250 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service    Boiler Room:  On or about 29 October 2013 and times prior thereto, a 120 volt Milwaukee 1/2" Impact Wrench, model number 9066, serial number 754A197100140 had a damaged cord exposing wiring.  This condition exposed employees to an electrical shock and burn hazard.       The Alaska Native Tribal Health Consortium was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 307504449, citation number 1, item number 3 and was affirmed as a final order on April 21, 2009, with respect to a workplace located at Alaska Native Tribal Health Consortium.
Recent events (2)
  • — I (S) $11250
  • — Z (R) $15000

View Alaska Native Tribal Health Consortium's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339454456.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.