Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANTERO RESOURCES CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ANTERO RESOURCES CORPORATION in JONATHON DAVIS WELL PAD, WEST UNION, WV 26456 (NAICS 213112). OSHA activity number 339454597.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Antero Resources Corporation — free Get an email when a new federal OSHA severe-injury report for Antero Resources Corporation is published. One employer, no account, unsubscribe in one click.
Site address
JONATHON DAVIS WELL PAD
City
WEST UNION
State
WV
ZIP
26456
Mailing
535 WHITE OAKS BOULEVARD, BRIDGEPORT, WV 26330
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
2
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2014
Abate by
May 28, 2014
Penalty
Initial $3,600 · Current $3,600
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm  to employees in that employees were exposed to fire and explosion hazards from an ignition source located in the area of flammable liquids and vapors while removing a dump valve assembly from a separator containing flammable condensate and vapors:     (a)  Jonathon Davis Pad:  Employees were removing a dump control unit from the low side of a three phase horizontal separator when flammable condensate was released from the vessel and ignited.  A burning pilot light on a separator located approximately 5 feet away did not have the pilot tube cap installed which provided an ignition source for the flammable condensate, as determined on October 29, 2013.     Abatement Certification Required for this Item.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $3600

View Antero Resources Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339454597.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.