OSHA Inspection: COLEMAN COMPANY, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLEMAN COMPANY, INC in 3600 N HYDRAULIC ST, WICHITA, KS 67219 (NAICS 326199). OSHA activity number 339455040.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coleman Company, INC — free Get an email when a new federal OSHA severe-injury report for Coleman Company, INC is published. One employer, no account, unsubscribe in one click.
Site address
3600 N HYDRAULIC ST
City
WICHITA
State
KS
ZIP
67219
Mailing
PO BOX 2931, WICHITA, KS 67201
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
712
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 75 exposed
Issued
Jan 31, 2014
Penalty
Initial $4,250 · Current $2,975 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   Employees operating blow mold machine number 7 to produce plastic cooler lids were exposed to caught-in/crush hazards in that; guard on the machine did not prevent employees from reaching the point where the die and ram stop come together, creating a pinch point.  The pinch point measured 19" from the front of the machine, and the opening measured 42.5" wide by 12.5" tall.  The bottom of the opening measured 36" from the floor.
Recent events (2)
  • — I (S) $2975
  • — Z (S) $4250

1910.147 C06 I C

Other-than-serious 1 instance 141 exposed
Issued
Jan 31, 2014
Abate by
Apr 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:   The periodic inspection of the energy control program did not a review between the inspector and each authorized employee.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Coleman Company, INC's full OSHA safety record →