NEPTUNE BEACH, FL —
OSHA Inspection: CJL SIDING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CJL SIDING, INC. in 115 ORANGE STREET, NEPTUNE BEACH, FL 32266 (NAICS 238170). OSHA activity number 339455776.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CJL SIDING, INC.
- Site address
- 115 ORANGE STREET
- City
- NEPTUNE BEACH
- State
- FL
- ZIP
- 32266
- Mailing
- 4304 PLAZA GATE LANE #203, JACKSONVILLE, FL 32217
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 G01
- Issued
- Nov 27, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a. On or about October 28, 2013, a siding installer working 12 feet and 6 inches from the ground on a pump jack scaffold did not use a guardrail while installing plywood siding on a two story house thereby exposing him to a fall hazard.
Recent events (1)
- — Z (S) $2800
1926.452 J02
- Issued
- Nov 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a. On or about October 28, 2013, the siding installer was working on a pump jack scaffold twelve feet six inches from the ground that was not braced at the bottom poles of the pump jack scaffold to the house's structure thereby he was exposed to a fall hazard.